PROTEIN SEPARATION WITH AQUEOUS AQUEOUS POLYMER SYSTEMS BY 2 TYPES OF COUNTERCURRENT CHROMATOGRAPHS

被引:43
作者
SHIBUSAWA, Y [1 ]
ITO, Y [1 ]
机构
[1] NHLBI,BIOPHYS CHEM LAB,BLDG 10,ROOM 7N322,BETHESDA,MD 20892
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 550卷 / 1-2期
关键词
COIL PLANET CENTRIFUGE; MULTILAYER COILS; PHASE SYSTEMS; PERFORMANCE; COLUMNS;
D O I
10.1016/S0021-9673(01)88575-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different types of counter-current chromatographs, the cross-axis coil planet centrifuge (X-axis CPC) and horizontal flow-through coil planet centrifuge (horizontal CPC), were evaluated for protein separation with an aqueous-aqueous two-phase polymer system. The sample solution, containing 10-200 mg each of cytochrome c, myoglobin, ovalbumin and hemoglobin in 2 ml of each phase was eluted with the lower phase. In both instruments, the effects of the flow-rate, revolution speed, and parameter beta-(helical diameters of the multilayer coil) on the protein separation were investigated. The best results were obtained from the X-axis CPC operated at 750 rpm and a flow-rate of 2.0 ml/min using a multilayer coil with a small helical diameter (beta = 0.25-0.60). Four protein samples were well resolved in less than 5 h.
引用
收藏
页码:695 / 704
页数:10
相关论文
共 12 条
[1]  
Albertsson P.A., 1986, PARTITION CELL PARTI
[2]  
Conway W.D., 1990, Countercurrent Chromatography: Apparatus, Theory and Applications
[3]  
ITO Y, 1986, CRIT REV ANAL CHEM, V17, P65, DOI 10.1080/10408348608542792
[4]   COUNTERCURRENT CHROMATOGRAPHY . LIQUID-LIQUID PARTITION CHROMATOGRAPHY WITHOUT SOLID SUPPORT [J].
ITO, Y ;
BOWMAN, RL .
SCIENCE, 1970, 167 (3916) :281-&
[5]   IMPROVED HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH WITH 3 MULTILAYER COILS CONNECTED IN SERIES .4. EVALUATION OF PREPARATIVE CAPABILITY WITH LARGE MULTILAYER COILS [J].
ITO, Y ;
KITAZUME, E ;
SLEMP, JL .
JOURNAL OF CHROMATOGRAPHY, 1991, 538 (01) :81-85
[6]   CROSS-AXIS SYNCHRONOUS FLOW-THROUGH COIL PLANET CENTRIFUGE (TYPE-XLL) .1. DESIGN OF THE APPARATUS AND STUDIES ON RETENTION OF STATIONARY PHASE [J].
ITO, Y ;
KITAZUME, E ;
BHATNAGAR, M ;
TRIMBLE, FD .
JOURNAL OF CHROMATOGRAPHY, 1991, 538 (01) :59-66
[7]   HORIZONTAL FLOW-THROUGH COIL PLANET CENTRIFUGE EQUIPPED WITH A SET OF MULTILAYER COILS AROUND THE COLUMN HOLDER - COUNTERCURRENT CHROMATOGRAPHY OF PROTEINS WITH A POLYMER-PHASE SYSTEM [J].
ITO, Y ;
OKA, H .
JOURNAL OF CHROMATOGRAPHY, 1988, 457 :393-397
[8]   APPLICATION OF ELUTION CENTRIFUGE TO SEPARATION OF POLYNUCLEOTIDES WITH USE OF POLYMER PHASE SYSTEMS [J].
ITO, Y ;
BOWMAN, RL .
SCIENCE, 1973, 182 (4110) :391-393
[9]   IMPROVED HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH WITH 3 MULTILAYER COILS CONNECTED IN SERIES .1. DESIGN OF THE APPARATUS AND PERFORMANCE OF SEMIPREPARATIVE COLUMNS IN 2,4-DINITROPHENYL AMINO-ACID SEPARATION [J].
ITO, Y ;
OKA, H ;
SLEMP, JL .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :219-227
[10]  
ITO Y, 1988, PRINCIPLE INSTRUMENT, P79