FACTORS INFLUENCING THE PRECISION OF QUANTITATIVE SCANNING-TRANSMISSION ELECTRON-MICROSCOPY

被引:141
作者
MULLER, SA
GOLDIE, KN
BURKI, R
HARING, R
ENGEL, A
机构
[1] M.E. Müller Institute for High-Resolution Electron Microscopy at the Biocentre, University of Basel
关键词
D O I
10.1016/0304-3991(92)90022-C
中图分类号
TH742 [显微镜];
学科分类号
摘要
The scanning transmission electron microscope (STEM) can be used for accurate and reproducible mass measurements. Here we analyse the major sources of systematic errors. Focus-dependent changes of the magnification can be corrected on-line by monitoring the objective-lens current. Post-specimen field effects are shown to be negligible for the Vacuum Generators STEM HB5 used. Operating conditions of the detector, a scintillator-photomultiplier combination, are critical and need to be calibrated for each experiment. The influence of sample purity, mass-loss kinetics and glutaraldehyde fixation on mass values is evaluated for several biological specimens, in particular for the widely used mass standard TMV. Possible errors arising from the use of mass standards to compensate for both instrumental and specimen-related uncertainties are considered.
引用
收藏
页码:317 / 334
页数:18
相关论文
共 49 条
  • [41] RADIAL DENSITY PROFILES OF MACROMOLECULAR FILAMENTS DETERMINED FROM DARK-FIELD SCANNING-TRANSMISSION ELECTRON-MICROGRAPHS - IMPROVEMENTS IN TECHNIQUE AND SOME APPLICATIONS
    STEVEN, AC
    SIMPSON, TA
    TRUS, BL
    FURCINITTI, PS
    HAINFELD, JF
    WALL, JS
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1986, 483 : 188 - 201
  • [42] STEVEN AC, 1983, J BIOL CHEM, V258, P8323
  • [43] RADIAL DISTRIBUTIONS OF DENSITY WITHIN MACROMOLECULAR COMPLEXES DETERMINED FROM DARK-FIELD ELECTRON-MICROGRAPHS
    STEVEN, AC
    HAINFELD, JF
    TRUS, BL
    STEINERT, PM
    WALL, JS
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1984, 81 (20): : 6363 - 6367
  • [44] VANHOLDE KE, 1971, PHYSICAL BIOCH
  • [45] WALL J S, 1979, Scanning Electron Microscopy, P291
  • [46] WALL JS, 1986, ANNU REV BIOPHYS BIO, V15, P355
  • [47] UNSHADOWED MYOSIN MOLECULES - STEM MASS-MAPS OF MYOSIN HEADS
    WALZTHONY, D
    BAHLER, M
    EPPENBERGER, HM
    WALLIMANN, T
    ENGEL, A
    [J]. EMBO JOURNAL, 1984, 3 (11) : 2621 - 2626
  • [48] STRUCTURAL CHARACTERIZATION OF THE CORE OF THE PAIRED HELICAL FILAMENT OF ALZHEIMER-DISEASE
    WISCHIK, CM
    NOVAK, M
    EDWARDS, PC
    KLUG, A
    TICHELAAR, W
    CROWTHER, RA
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (13) : 4884 - 4888
  • [49] WITMAN GB, 1983, J SUBMICR CYTOL PATH, V15, P193