LIQUID-CHROMATOGRAPHIC ANALYSIS OF MESNA AND DIMESNA IN PLASMA AND URINE OF PATIENTS TREATED WITH MESNA

被引:16
作者
ELYAZIGI, A
YUSUF, A
ALRAWITHI, S
机构
[1] Pharmacokinetics Laboratory and Pharmacology and Toxicology Section, Department of Biological and Medical Research, King Faisal Specialist Hospital and Research Centre, Riyadh
关键词
MESNA; DIMESNA; ANALYSIS; BLOOD; URINE; BONE MARROW TRANSPLANTATION;
D O I
10.1097/00007691-199504000-00009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We describe in this report an expedient and accurate liquid chromatographic method for measurement of mesna and dimesna in plasma and urine. The separation of mesna and the internal standard (p-aminobenzoic acid, IS) was achieved on a 10-mu m, 8 mm (i.d.) x 10-cm C-18-Resolve cartridge in conjunction with radial compression system. An aqueous solution of sodium citrate (0.1 M), tetrabutyl ammonium phosphate (0.001 M), and triethylamine (1:10,000, vol/vol), adjusted to pH 5 with 85% phosphoric acid was used at a flow rate of 2 ml/min as a mobile phase. The compounds were detected in the effluent electrochemically at +450 mV. After an appropriate amount of IS was added, the plasma sample (100 mu l or fraction thereof) was deproteinized with an equal volume of 0.0825 M sulfuric acid containing sodium hexametaphosphate (1.25% wt/vol), whereas urine was diluted 1:50 with water and mixed 1:1 with an aqueous solution of sodium hexametaphosphate (1.25% wt/vol). Dimesna was reduced back to mesna with sodium borohydride before analysis of the total mesna. The peak height ratio (drug/IS) varied linearly with the concentration, and the correlation coefficient was >0.992 for both mesna and di mesna. The intrarun precision at different concentrations of mesna was equally good and the coefficient of variation was consistently <4.5%. No interference from endogenous substances or any concomitantly used drug was observed. This assay is currently being used for measurement of mesna and dimesna in plasma of bone marrow recipients who receive high doses of cyclophosphamide.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 9 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF SOME COENZYME-M (2-MERCAPTOETHANESULFONIC ACID) DERIVATIVES BY ION-PAIRING ON REVERSED-PHASE COLUMNS [J].
APOSTOLIDES, Z ;
VERMEULEN, NMJ ;
POTGIETER, DJJ .
JOURNAL OF CHROMATOGRAPHY, 1982, 246 (02) :304-307
[2]   PHARMACOKINETICS AND MECHANISM OF ACTION OF DETOXIFYING LOW-MOLECULAR-WEIGHT THIOLS [J].
BROCK, N ;
HILGARD, P ;
POHL, J ;
ORMSTAD, K ;
ORRENIUS, S .
JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 1984, 108 (01) :87-97
[3]  
BROCK N, 1980, BEITRAGE ONKOLOGIE, V5, P1
[4]   CYCLOPHOSPHAMIDE-ASSOCIATED CARCINOMA OF UROTHELIUM - MODALITIES FOR PREVENTION [J].
CANNON, J ;
LINKE, CA ;
COS, LR .
UROLOGY, 1991, 38 (05) :413-416
[5]   CYCLOPHOSPHAMIDE CYSTITIS - IDENTIFICATION OF ACROLEIN AS THE CAUSATIVE AGENT [J].
COX, PJ .
BIOCHEMICAL PHARMACOLOGY, 1979, 28 (13) :2045-2049
[6]   TISSUE SULFHYDRYL GROUPS [J].
ELLMAN, GL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1959, 82 (01) :70-77
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ALIPHATIC THIOLS WITH AROYLACRYLIC ACIDS AS FLUOROGENIC PRECOLUMN DERIVATIZATION REAGENTS [J].
GATTI, R ;
CAVRINI, V ;
ROVERI, P ;
PINZAUTI, S .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :451-458
[8]   ESTIMATION OF MESNA AND DIMESNA IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
JAMES, CA ;
ROGERS, HJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 382 :394-398
[9]   DETERMINATION OF SODIUM 2-MERCAPTOETHANESULFONATE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING POST-COLUMN REACTION COLORIMETRY OR ELECTROCHEMICAL DETECTION [J].
SIDAU, B ;
SHAW, IC .
JOURNAL OF CHROMATOGRAPHY, 1984, 311 (01) :234-238