THE ROLE OF NOISE IN THE MEASUREMENT OF CEREBRAL BLOOD-FLOW AND PARTITION-COEFFICIENT USING XENON-ENHANCED COMPUTED-TOMOGRAPHY

被引:5
作者
BEWS, J [1 ]
DUNSCOMBE, PB [1 ]
LEE, TY [1 ]
MCCLARTY, B [1 ]
KROEKER, MA [1 ]
机构
[1] ST BONIFACE GEN HOSP,DEPT RADIOL,WINNIPEG R2H 2A6,MANITOBA,CANADA
关键词
D O I
10.1088/0031-9155/35/7/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulations have been used to study the accuracy which can be expected in the quantification of blood flow and the partition coefficient using xenon-enhanced computed tomography in the presence of noise. The authors have demonstrated that the markedly asymmetric frequency distribution of estimates increases in size rapidly with an increase in the standard error of the input CT data. On the basis of their results the authors recommend that controllable sources of noise (e.g. CT number drift) be corrected and that estimates be obtained by averaging CT data and then fitting, rather than averaging CT data and then fitting, rather than averaging blood flow and partition coefficients derived from individual pixels, as the latter procedure results in the introduction of considerable bias.
引用
收藏
页码:937 / 945
页数:9
相关论文
共 9 条
[1]   EXPERIMENTAL XENON ENHANCEMENT WITH CT IMAGING - CEREBRAL APPLICATIONS [J].
DRAYER, BP ;
GUR, D ;
WOLFSON, SK ;
COOK, EE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (01) :39-44
[2]   XENON CONTRAST ENHANCEMENT IN COMPUTED BODY TOMOGRAPHY [J].
FOLEY, WD ;
HAUGHTON, VM ;
SCHMIDT, J ;
WILSON, CR .
RADIOLOGY, 1978, 129 (01) :219-220
[3]   THE EFFECT OF COMPUTED-TOMOGRAPHY NOISE AND TISSUE HETEROGENEITY ON CEREBRAL BLOOD-FLOW DETERMINATION BY XENON-ENHANCED COMPUTED-TOMOGRAPHY [J].
GOOD, WF ;
GUR, D .
MEDICAL PHYSICS, 1987, 14 (04) :557-561
[4]   ERRORS IN CEREBRAL BLOOD-FLOW DETERMINATIONS BY XENON-ENHANCED COMPUTED-TOMOGRAPHY DUE TO ESTIMATION OF ARTERIAL XENON CONCENTRATIONS [J].
GOOD, WF ;
GUR, D ;
YONAS, H ;
HERRON, JM .
MEDICAL PHYSICS, 1987, 14 (03) :377-381
[5]   SIMULTANEOUS MASS-SPECTROMETRY AND THERMOCONDUCTIVITY MEASUREMENTS OF END-TIDAL XENON CONCENTRATIONS - A COMPARISON [J].
GUR, D ;
HERRON, JM ;
MOLTER, BS ;
GOOD, BC ;
ALBRIGHT, RE ;
MILLER, JN ;
DRAYER, BP .
MEDICAL PHYSICS, 1984, 11 (02) :209-212
[6]  
KEARFOTT KJ, 1984, MED PHYS, V11, P686, DOI 10.1118/1.595552
[7]  
KETY S, 1951, PHARMACOL REV, V8, P228
[8]   QUANTITATIVE COMPUTED-TOMOGRAPHY OF THE BRAIN WITH XENON ENHANCEMENT - A PHANTOM STUDY WITH THE GE9800 SCANNER [J].
LEE, TY ;
ELLIS, RJ ;
DUNSCOMBE, PB ;
MCCLARTY, B ;
HODSON, DI ;
KROEKER, MA ;
BEWS, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07) :925-935
[9]   MAPPING LOCAL BLOOD-FLOW OF HUMAN-BRAIN BY CT SCANNING DURING STABLE XENON INHALATION [J].
MEYER, JS ;
HAYMAN, LA ;
AMANO, T ;
NAKAJIMA, S ;
SHAW, T ;
LAUZON, P ;
DERMAN, S ;
KARACAN, I ;
HARATI, Y .
STROKE, 1981, 12 (04) :426-436