QUANTITATIVE COMPUTED-TOMOGRAPHY OF THE BRAIN WITH XENON ENHANCEMENT - A PHANTOM STUDY WITH THE GE9800 SCANNER

被引:22
作者
LEE, TY
ELLIS, RJ
DUNSCOMBE, PB
MCCLARTY, B
HODSON, DI
KROEKER, MA
BEWS, J
机构
[1] MANITOBA CANC TREATMENT & RES FDN,DEPT MED PHYS,100 OLIVIA ST,WINNIPEG R3E 0V9,MANITOBA,CANADA
[2] MANITOBA CANC TREATMENT & RES FDN,DEPT RADIAT ONCOL,WINNIPEG R3E 0V9,MANITOBA,CANADA
[3] ST BONIFACE GEN HOSP,DEPT RADIOL,WINNIPEG R2H 2A6,MANITOBA,CANADA
关键词
D O I
10.1088/0031-9155/35/7/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A recently proposed application of quantitative computed tomography is in the study of cerebral blood flow and partition coefficient using stable xenon as a freely diffusible, radio-opaque tracer. Central to the method is the calibration factor describing the relationship between CT number and xenon concentration in the brain. The authors examine the influence of temporal fluctuations, kVp, radial position and beam hardening on this calibration factor through the analysis of a series of phantom measurements. It is concluded that under clinically realistic conditions and with corrections for temporal fluctuations, the error associated with the calibration factor is less than 2%. Furthermore, errors of this magnitude translate into errors of less than 3% in derived blood flow and partition coefficient values obtained using xenon-enhanced computed tomography.
引用
收藏
页码:925 / 935
页数:11
相关论文
共 8 条
[1]   THE ROLE OF NOISE IN THE MEASUREMENT OF CEREBRAL BLOOD-FLOW AND PARTITION-COEFFICIENT USING XENON-ENHANCED COMPUTED-TOMOGRAPHY [J].
BEWS, J ;
DUNSCOMBE, PB ;
LEE, TY ;
MCCLARTY, B ;
KROEKER, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07) :937-945
[2]  
DRAYER B, 1979, Acta Neurologica Scandinavica Supplementum, V60, P218
[3]   SIMULTANEOUS MASS-SPECTROMETRY AND THERMOCONDUCTIVITY MEASUREMENTS OF END-TIDAL XENON CONCENTRATIONS - A COMPARISON [J].
GUR, D ;
HERRON, JM ;
MOLTER, BS ;
GOOD, BC ;
ALBRIGHT, RE ;
MILLER, JN ;
DRAYER, BP .
MEDICAL PHYSICS, 1984, 11 (02) :209-212
[4]  
KEARFOTT KJ, 1983, AM J NEURORADIOL, V4, P195
[5]   COMPUTED TOMOGRAPHIC MEASUREMENT OF XENON BRAIN-BLOOD PARTITION-COEFFICIENT AND IMPLICATIONS FOR REGIONAL CEREBRAL BLOOD-FLOW - PRELIMINARY-REPORT [J].
KELCZ, F ;
HILAL, SK ;
HARTWELL, P ;
JOSEPH, PM .
RADIOLOGY, 1978, 127 (02) :385-392
[6]  
KETY SS, 1951, PHARMACOL REV, V3, P1
[7]  
SPOKAS T, 1983, MED PHYS, V9, P288
[8]   EPOXY-RESIN BASED TISSUE SUBSTITUTES [J].
WHITE, DR ;
MARTIN, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1977, 50 (599) :814-821