EFFECTS OF DEFOCUS AND PRIMARY SPHERICAL-ABERRATION ON 3-DIMENSIONAL COHERENT TRANSFER-FUNCTIONS IN CONFOCAL MICROSCOPES

被引:17
作者
GU, M
SHEPPARD, CJR
机构
[1] Department of Physical Optics, University of Sydney, Sydney, NSW
关键词
D O I
10.1364/AO.31.002541
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For both reflection- and transmission-mode confocal scanning microscope systems, three-dimensional coherent transfer functions are investigated by considering the effects of defocus and primary spherical aberration. We numerically calculate the three-dimensional coherent transfer functions for various amounts of aberration and show that three-dimensional confocal imaging is strongly degraded if the amount of aberration is larger than a quarter wavelength. The compensation of the primary spherical aberration by introducing defocus is also discussed.
引用
收藏
页码:2541 / 2549
页数:9
相关论文
共 14 条
[11]  
SHEPPARD CJR, 1991, OPTIK, V87, P34
[12]  
SHEPPARD CJR, 1987, ADV OPTICAL ELECTRON, V10, P1
[13]   EFFECTS OF 3RD-ORDER SPHERICAL-ABERRATION ON THE 3-D INCOHERENT OPTICAL TRANSFER-FUNCTION [J].
WANG, S ;
FRIEDEN, BR .
APPLIED OPTICS, 1990, 29 (16) :2424-2432
[14]  
Wilson T, 1984, THEORY PRACTICE SCAN