COMPARISON OF ISOCRATIC AND GRADIENT ELUTION REVERSED-PHASE BEHAVIOR OF HIGH-MOLECULAR-MASS POLYSTYRENES IN DICHLOROMETHANE AND ACETONITRILE

被引:8
作者
SHALLIKER, RA
KAVANAGH, PE
RUSSELL, IM
机构
[1] DEAKIN UNIV,SCH BIOL & CHEM SCI,WAURN PONDS,VIC 3217,AUSTRALIA
[2] CSIRO,DIV WOOL TECHNOL,BELMONT,VIC 3216,AUSTRALIA
关键词
D O I
10.1016/0021-9673(94)80316-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Isocratic and gradient elution of high-molecular-mass polystyrenes were compared in a dichloromethane-acetonitrile mobile phase and C-18 bonded phase on a variety of different pore size silicas. Plots of the capacity factor versus the solvent composition were drawn from which solvent strength parameters, S, were determined for different molecular masses. Linear gradient elution data were also used to estimate S values using a graphical procedure. It was found that S depended on gradient rate and that only gradient rates of less than 2%/min gave constant values of S. Only molecular masses less than 50 000 gave good agreement with isocratic values. Plots of log S against log molecular mass were different for isocratic and gradient determined values of S.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 20 条
[11]   ISOCRATIC ELUTION OF HIGH MOLECULAR-WEIGHT MONODISPERSE POLYSTYRENES [J].
LOCHMULLER, CH ;
MCGRANAGHAN, MB .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2449-2455
[12]   LIQUID-CHROMATOGRAPHIC RETENTION BEHAVIOR OF POLYSTYRENE HOMOPOLYMERS ON A C4, BIMODAL PORE DIAMETER, REVERSED-PHASE COLUMN [J].
NORTHROP, DM ;
MARTIRE, DE ;
SCOTT, RPW .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :16-21
[13]   PREDICTION OF PRECISE ISOCRATIC RETENTION DATA FROM 2 OR MORE GRADIENT ELUTION RUNS - ANALYSIS OF SOME ASSOCIATED ERRORS [J].
QUARRY, MA ;
GROB, RL ;
SNYDER, LR .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :907-917
[14]  
SCHOENMAKERS PJ, 1979, J CHROMATOGR, V185, P179
[15]   SYSTEMATIC STUDY OF TERNARY SOLVENT BEHAVIOR IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
SCHOENMAKERS, PJ ;
BILLIET, HAH ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :261-284
[16]   REVERSED-PHASE SEPARATIONS OF HIGH-MOLECULAR-WEIGHT POLYSTYRENES IN A DICHLOROMETHANE ACETONITRILE SOLVENT SYSTEM [J].
SHALLIKER, RA ;
KAVANAGH, PE ;
RUSSELL, IM .
JOURNAL OF CHROMATOGRAPHY, 1991, 558 (02) :440-445
[17]   SEPARATIONS OF HIGH-MOLECULAR-MASS POLYSTYRENES ON DIFFERENT PORE-SIZE AND PARTICLE-SIZE REVERSED-PHASE COLUMNS IN DICHLOROMETHANE-ACETONITRILE [J].
SHALLIKER, RA ;
KAVANAGH, PE ;
RUSSELL, IM .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (02) :221-228
[18]  
SHALLIKER RA, 1992, THESIS DEAKIN U WAUR
[19]  
Snyder L.R., 1980, HIGH PERFORMANCE LIQ, V1, P207
[20]   GRADIENT ELUTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. THEORETICAL BASIS FOR REVERSED-PHASE SYSTEMS [J].
SNYDER, LR ;
DOLAN, JW ;
GANT, JR .
JOURNAL OF CHROMATOGRAPHY, 1979, 165 (01) :3-30