摘要
A simple analytical model is presented for the transport of secondary electrons at a photon beam edge using the energy averaged solution of the Boltzmann equation, originally developed for beta-ray dosimetry at a plane interface. Dose at a point under a block is assumed to be due to secondary electrons and the scattered photons generated from the primary photon beam. The diffusion approximation is used for the secondary electron transport at a virtual plane interface created by the block. The dose from the scattered photon component is treated as decaying exponentially with distance from the beam edge. Comparisons made with the model and measurements are in general agreement for high energy accelerator beams.
引用
收藏
页码:937 / 946
页数:10
相关论文
共 18 条
[1]  
BLOCH P, 1979, Medical Physics (Woodbury), V6, P149, DOI 10.1118/1.594527
[2]   THE DEPENDENCE OF MASS-ENERGY ABSORPTION-COEFFICIENT RATIOS ON BEAM SIZE AND DEPTH IN A PHANTOM [J].
CUNNINGHAM, JR ;
WOO, M ;
ROGERS, DWO ;
BIELAJEW, AF .
MEDICAL PHYSICS, 1986, 13 (04) :496-502
[4]   ANALYSIS OF PHYSICAL PARAMETERS ASSOCIATED WITH THE MEASUREMENT OF HIGH-ENERGY X-RAY PENUMBRA [J].
DAWSON, DJ ;
HARPER, JM ;
AKINRADEWO, AC .
MEDICAL PHYSICS, 1984, 11 (04) :491-497
[5]   THE EFFECT OF SECONDARY-ELECTRON SPREAD ON THE PENUMBRA IN HIGH-ENERGY PHOTON-BEAM THERAPY [J].
DAY, MJ ;
LAMBERT, GD ;
LOCKS, SM .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (748) :278-285
[6]  
Fraass B. A., 1987, USE COMPUTERS RAD TH, P521
[7]  
JOHNS HE, 1983, PHYSICS RADIOLOGY
[8]   MEASUREMENTS OF DOSE FROM SECONDARY RADIATION OUTSIDE A TREATMENT FIELD [J].
KASE, KR ;
SVENSSON, GK ;
WOLBARST, AB ;
MARKS, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (08) :1177-1183
[9]   DOSIMETRY OF ASYMMETRIC X-RAY COLLIMATORS [J].
KHAN, FM ;
GERBI, BJ ;
DEIBEL, FC .
MEDICAL PHYSICS, 1986, 13 (06) :936-941
[10]   CHOICE OF OPTIMUM MEGAVOLTAGE FOR ACCELERATORS FOR PHOTON-BEAM TREATMENT [J].
LAUGHLIN, JS ;
MOHAN, R ;
KUTCHER, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (09) :1551-1557