摘要
The aim of this study was to compare a commercially available PCR kit (Amplicor, Roche) with our present routine analysis (SYVA EIA) for the detection of genital C. trachomatis infection in females. Furthermore, we wished to investigate the possibility of pooling samples for PCR analysis. Two hundred and sixty-eight consecutive female patients attending two gynecology clinics in Copenhagen, Denmark were included in this study. Compared to the number of samples regarded as true positives, PCR had a sensitivity of 100% (18/18) and EIA a sensitivity of 83.3% (15/18). The specificity of the PCR analysis was 99.2% (248/250) compared to 100% (250/250) for the EIA. By pooling patient samples (five patient samples in each pooled sample), a 39% reduction in reagent costs was obtained without affecting the sensitivity. In conclusion, the implementation of a standardized commercially available C, trachomatis PCR kit leads to a marked increase in analytical sensitivity compared to EIA without affecting the specificity. When pooled samples were analyzed, the cost per patient sample was reduced, but further large-scale studies are needed to rule out the possibility of a reduced sensitivity due to the dilution of individual patient samples.
引用
收藏
页码:797 / 800
页数:4
相关论文
共 19 条
[1]   LABORATORY DIAGNOSIS OF HUMAN CHLAMYDIAL INFECTIONS [J].
BARNES, RC .
CLINICAL MICROBIOLOGY REVIEWS, 1989, 2 (02) :119-136
[2]   CLINICAL-EVALUATION OF A NEW POLYMERASE CHAIN-REACTION ASSAY FOR DETECTION OF CHLAMYDIA-TRACHOMATIS IN ENDOCERVICAL SPECIMENS [J].
BASS, CA ;
JUNGKIND, DL ;
SILVERMAN, NS ;
BONDI, JM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (10) :2648-2653
[3]   DIAGNOSIS OF CHLAMYDIA-TRACHOMATIS ENDOCERVICAL INFECTIONS BY A COMMERCIAL POLYMERASE CHAIN-REACTION ASSAY [J].
BAUWENS, JE ;
CLARK, AM ;
STAMM, WE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (11) :3023-3027
[4]  
CLAAS HC, 1990, EUR J CLIN MICROBIOL, V9, P964
[5]   DETECTION OF CHLAMYDIA-TRACHOMATIS BY THE POLYMERASE CHAIN-REACTION [J].
GRIFFAIS, R ;
THIBON, M .
RESEARCH IN MICROBIOLOGY, 1989, 140 (02) :139-141
[6]   COMPARISON OF THE GEN-PROBE PACE-2 SYSTEM, DIRECT FLUORESCENT-ANTIBODY, AND CELL-CULTURE FOR DETECTING CHLAMYDIA-TRACHOMATIS IN CERVICAL SPECIMENS [J].
IWEN, PC ;
BLAIR, TMH ;
WOODS, GL .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1991, 95 (04) :578-582
[7]  
KELLOGG JA, 1989, ARCH PATHOL LAB MED, V113, P453
[8]   EVALUATION OF CLEARVIEW AND MAGIC LITE TESTS, POLYMERASE CHAIN-REACTION, AND CELL-CULTURE FOR DETECTION OF CHLAMYDIA-TRACHOMATIS IN UROGENITAL SPECIMENS [J].
KLUYTMANS, JAJW ;
GOESSENS, WHF ;
MOUTON, JW ;
VANRIJSOORTVOS, JH ;
NIESTERS, HGM ;
QUINT, WGV ;
HABBEMA, L ;
STOLZ, E ;
WAGENVOORT, JHT .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (12) :3204-3210
[9]   AVOIDING FALSE POSITIVES WITH PCR [J].
KWOK, S ;
HIGUCHI, R .
NATURE, 1989, 339 (6221) :237-238
[10]   DEVELOPMENT AND CLINICAL-EVALUATION OF A POLYMERASE CHAIN-REACTION TEST FOR DETECTION OF CHLAMYDIA-TRACHOMATIS [J].
OSSEWAARDE, JM ;
RIEFFE, M ;
ROZENBERGARSKA, M ;
OSENKOPPELE, PM ;
NAWROCKI, RP ;
VANLOON, AM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (08) :2122-2128