THE NEER-CLASSIFICATION-SYSTEM FOR PROXIMAL HUMERAL FRACTURES - AN ASSESSMENT OF INTEROBSERVER RELIABILITY AND INTRAOBSERVER REPRODUCIBILITY

被引:286
作者
SIDOR, ML
ZUCKERMAN, JD
LYON, T
KOVAL, K
CUOMO, F
SCHOENBERG, N
机构
[1] Shoulder Service, Joint Dis. Orthopaedic Inst. Hosp., New York, NY 10003
关键词
D O I
10.2106/00004623-199312000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The radiographs of fifty fractures of the proximal part of the humerus were used to assess the interobserver reliability and intraobserver reproducibility of the Neer classification system. A trauma series consisting of scapular anteroposterior, scapular lateral, and axillary radiographs was available for each fracture. The radiographs were reviewed by an orthopaedic shoulder specialist, an orthopaedic traumatologist, a skeletal radiologist, and two orthopaedic residents, in their fifth and second years of postgraduate training. The radiographs were reviewed on two different occasions, six months apart. Interobserver reliability was assessed by comparison of the fracture classifications determined by the five observers. Intraobserver reproducibility was evaluated by comparison of the classifications determined by each observer on the first and second viewings. Kappa (kappa) reliability coefficients were used. All five observers agreed on the final classification for 32 and 30 per cent of the fractures on the first and second viewings, respectively. Paired comparisons between the five observers showed a mean reliability coefficient of 0.48 (range, 0.43 to 0.58) for the first viewing and 0.52 (range, 0.37 to 0.62) for the second viewing. The attending physicians obtained a slightly higher kappa value than the orthopaedic residents (0.52 compared with 0.48). Reproducibility ranged from 0.83 (the shoulder specialist) to 0.50 (the skeletal radiologist),,vith a mean of 0.66. Simplification of the Neer classification system, from sixteen categories to six more general categories based on fracture type, did not significantly improve either interobserver reliability or intraobserver reproducibility.
引用
收藏
页码:1745 / 1750
页数:6
相关论文
共 17 条
[11]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[12]   FRACTURES OF THE PROXIMAL HUMERUS IN ADULTS [J].
MILLS, HJ ;
HORNE, G .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1985, 25 (08) :801-805
[15]   LAUGE-HANSEN CLASSIFICATION OF MALLEOLAR FRACTURES - AN ASSESSMENT OF THE REPRODUCIBILITY IN 118 CASES [J].
NIELSEN, JO ;
DONSJENSEN, H ;
SORENSEN, HT .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (05) :385-387
[16]  
SEEMANN WR, 1986, EUR J RADIOL, V6, P163
[17]   OBSERVER VARIATION IN THE RADIOGRAPHIC CLASSIFICATION OF ANKLE FRACTURES [J].
THOMSEN, NOB ;
OVERGAARD, S ;
OLSEN, LH ;
HANSEN, H ;
NIELSEN, ST .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :676-678