STOPPED-FLOW EPICARDIAL LYMPH PRESSURE IS AFFECTED BY LEFT-VENTRICULAR PRESSURE IN ANESTHETIZED GOATS

被引:7
作者
HAN, Y [1 ]
VERGROESEN, I [1 ]
SPAAN, JAE [1 ]
机构
[1] UNIV AMSTERDAM, FAC MED, DEPT MED PHYS & MED INFORMAT, MEIBERGDREEF 15, 1105 AZ AMSTERDAM, NETHERLANDS
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1993年 / 264卷 / 05期
关键词
CORONARY CIRCULATION; INTRAMYOCARDIAL COMPLIANCE; INTRAMYOCARDIAL PRESSURE;
D O I
10.1152/ajpheart.1993.264.5.H1624
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We measured epicardial lymph pressure (P(lymph)) in the anesthetized goat (n = 5 goats). To study the transmission of systolic left ventricular pressure (P(LV)) to P(lymph), the effect of an increase in P(LV) caused by clamping of the descending aorta on P(lymph) was evaluated. Peak systolic P(LV) was 131 +/- 4 (+/- SE) mmHg during control (43 beats) and 188 +/- 4 mmHg when elevated due to aortic clamping (157 beats). Peak systolic P(lymph) was 24.8 +/- 1.0 and 34.8 +/- 1.1 mmHg during control and elevated P(LV), respectively. In the first beat of elevated P(LV), peak P(lymph) did not change, although the pressure waveform did. In the subsequent beats, P(lymph) increased proportionally with increased P(LV). When P(LV) was decreased back to control, P(lymph) also decreased but did not reach control level until after three beats. The relationship between normalized P(lymph) and normalized P(LV) is given by P(lymph) = 0.70 . P(LV) + 0.09. The results show that P(LV) does affect P(lymph) in a normal beating heart.
引用
收藏
页码:H1624 / H1628
页数:5
相关论文
共 19 条
[11]   LYMPHATIC VESSELS OF MAMMALIAN HEART [J].
LEAK, LV ;
SCHANNAHAN, A ;
SCULLY, H ;
DAGGETT, WM .
ANATOMICAL RECORD, 1978, 191 (02) :183-&
[12]   The morphology of the lymphatics of the mammalian heart [J].
Patek, PR .
AMERICAN JOURNAL OF ANATOMY, 1939, 64 (02) :203-249
[13]   INTRAMYOCARDIAL PRESSURE - INTERACTION OF MYOCARDIAL FLUID PRESSURE AND FIBER STRESS [J].
RABBANY, SY ;
KRESH, JY ;
NOORDERGRAAF, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (02) :H357-H364
[14]   MICROLYMPHATICS AND LYMPH-FLOW [J].
SCHMIDSCHONBEIN, GW .
PHYSIOLOGICAL REVIEWS, 1990, 70 (04) :987-1028
[15]   DIASTOLIC-SYSTOLIC CORONARY FLOW DIFFERENCES ARE CAUSED BY INTRAMYOCARDIAL PUMP ACTION IN THE ANESTHETIZED DOG [J].
SPAAN, JAE ;
BREULS, NPW ;
LAIRD, JD .
CIRCULATION RESEARCH, 1981, 49 (03) :584-593
[16]   LOAD INDEPENDENCE OF INSTANTANEOUS PRESSURE-VOLUME RATIO OF CANINE LEFT VENTRICLE AND EFFECTS OF EPINEPHRINE AND HEART-RATE ON RATIO [J].
SUGA, H ;
SAGAWA, K ;
SHOUKAS, AA .
CIRCULATION RESEARCH, 1973, 32 (03) :314-322
[17]   SUBENDOCARDIAL CORONARY COMPRESSION IN BEATING DOG HEARTS IS INDEPENDENT OF PRESSURE IN THE VENTRICULAR LUMEN [J].
VANWINKLE, DM ;
SWAFFORD, AN ;
DOWNEY, JM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 261 (02) :H500-H505
[19]   EFFECT OF SUDDEN CHANGES IN AORTIC PRESSURE ON LEFT VENTRICULAR DP /DT [J].
WILDENTHAL, K ;
MIERZWIAK, DS ;
MITCHELL, JH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1969, 216 (01) :185-+