A DISPOSABLE AMPEROMETRIC IMMUNOSENSOR FOR 2,4-DICHLOROPHENOXYACETIC ACID

被引:88
作者
KALAB, T [1 ]
SKLADAL, P [1 ]
机构
[1] MASARYK UNIV,DEPT BIOCHEM,CR-61137 BRNO,CZECH REPUBLIC
关键词
AMPEROMETRY; BIOSENSORS; 2,4-DICHLOROPHENOXYACETIC ACID; HYDROQUINONE;
D O I
10.1016/0003-2670(94)00641-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable immunochemical biosensor for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) was developed using a screen-printed electrode system as an amperometric transducer and monoclonal antibodies against 2,4-D as a biospecific part. At first, the electrochemical system for determination of peroxidase activity was studied. For measurements, the peroxidase substrates were hydrogen peroxide together with either hydroquinone, 1,2-phenylenediamine or pyrocatechol as electron donors, which were amperometrically detected using platinum, gold and graphite composite layers as working electrode materials. The optimal concentrations of reaction components were found, the highest signals being achieved for hydroquinone with gold or graphite electrodes. The immunochemical system makes use of the competitive assay principle with 2,4-D covalently immobilized either directly on the surface of the gold electrode or on a separate nylon membrane. The peroxidase-antibody conjugate was synthesized and used as a tracing reagent. By using 2,4-D immobilized through its carboxylic group directly to the silanized surface of the gold working electrode, a detection limit close to 0.1 mu g/l of free 2,4-D was achieved. One analysis was completed in 1 h (30 min for the immunochemical reaction, washing, 25 min incubation with substrate, measurement).
引用
收藏
页码:361 / 368
页数:8
相关论文
共 31 条
[21]  
RENNEBERG R, 1992, GBF MONOG SERIES, V17, P25
[22]   A RADIOIMMUNOASSAY TO SCREEN FOR 2,4-DICHLOROPHENOXYACETIC ACID AND 2,4,5-TRICHLOROPHENOXYACETIC ACID IN SURFACE-WATER [J].
RINDER, DF ;
FLEEKER, JR .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1981, 26 (03) :375-380
[23]  
RITTENBURG JH, 1991, ACS SYM SER, V451, P28
[24]  
Roberts T. R., 1991, Chemistry, agriculture and the environment., P429
[25]   ENVIRONMENTAL CHEMISTRY - THE IMMUNOASSAY OPTION [J].
SHERRY, JP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (04) :217-300
[26]   CHARACTERIZATION OF MONOCLONAL-ANTIBODIES TO 2,4-DICHLOROPHENOXYACETIC ACID USING A PIEZOELECTRIC QUARTZ-CRYSTAL MICROBALANCE IN SOLUTION [J].
SKLADAL, P ;
MINUNNI, M ;
MASCINI, M ;
KOLAR, V ;
FRANEK, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 176 (01) :117-125
[27]   COMPOSITE ELECTRODES FOR ELECTROANALYSIS - PRINCIPLES AND APPLICATIONS [J].
TALLMAN, DE ;
PETERSEN, SL .
ELECTROANALYSIS, 1990, 2 (07) :499-510
[28]   IMMUNOCHEMICAL METHODS - FOR ENVIRONMENTAL-ANALYSIS [J].
VANEMON, JM ;
LOPEZAVILA, V .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :A79-A88
[29]   DEVELOPMENT OF AN ELISA FOR THE ANALYSIS OF ATRAZINE METABOLITES DEETHYLATRAZINE AND DEISOPROPYLATRAZINE [J].
WITTMANN, C ;
HOCK, B .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (06) :1194-1200