EVALUATION OF MYOCARDIAL MOTION TRACKING WITH CINE-PHASE CONTRAST MAGNETIC-RESONANCE-IMAGING

被引:66
作者
PELC, LR
SAYRE, J
YUN, K
CASTRO, LJ
HERFKENS, RJ
MILLER, DC
PELC, NJ
机构
[1] STANFORD UNIV,SCH MED,DEPT CARDIOTHORAC SURG,STANFORD,CA 94305
[2] VALLEY RADIOLOGISTS,RENTON,WA
关键词
MYOCARDIAL MOTION; PHASE CONTRAST; MAGNETIC RESONANCE STUDIES;
D O I
10.1097/00004424-199412000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The accuracy of myocardial motion measurements, computed from cine-phase contrast (cine-PC) magnetic resonance (MR) velocity data, was compared with directly visualized motion of MR signal voids caused by implanted tantalum markers in anesthetized dogs. METHODS. Magnetic resonance imaging (MRI) data were electrocardiogram-gated and divided into 16 phases per cardiac cycle, Myocardial trajectories as a function of time in the cardiac cycle were measured using both methods for four to seven markers in each of eight animals. RESULTS. The peak observed in-plane excursion was 4.0 +/- 2.1 mm, The average deviation between displacements derived from velocity data versus displacements visualized directly was 1.1 +/- 0.7 mm (27.5% of the peak displacement), The difference was less if three separate MR scans were used to measure each velocity component in the cine-PC method, This improvement is probably caused by improved temporal resolution. CONCLUSIONS. Cine-PC MRI offers a noninvasive method for accurate quantification of myocardial motion.
引用
收藏
页码:1038 / 1042
页数:5
相关论文
共 17 条
[1]   REGIONAL HEART WALL MOTION - 2-DIMENSIONAL ANALYSIS AND FUNCTIONAL IMAGING WITH MR IMAGING [J].
AXEL, L ;
GONCALVES, RC ;
BLOOMGARDEN, D .
RADIOLOGY, 1992, 183 (03) :745-750
[2]   NONINVASIVE QUANTIFICATION OF PRINCIPAL STRAINS IN NORMAL CANINE HEARTS USING TAGGED MRI IMAGES IN 3-D [J].
AZHARI, H ;
WEISS, JL ;
ROGERS, WJ ;
SIU, CO ;
ZERHOUNI, EA ;
SHAPIRO, EP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (01) :H205-H216
[3]   MYOCARDIAL TAGGING IN POLAR COORDINATES WITH USE OF STRIPED TAGS [J].
BOLSTER, BD ;
MCVEIGH, ER ;
ZERHOUNI, EA .
RADIOLOGY, 1990, 177 (03) :769-772
[4]  
CASTRO LJ, 1993, J THORAC CARDIOV SUR, V105, P643
[5]  
CONSTABLE RT, IN PRESS MAG RES MED
[6]   MEASUREMENT OF SKELETAL-MUSCLE MOTION IN-VIVO WITH PHASE-CONTRAST MR-IMAGING [J].
DRACE, JE ;
PELC, NJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :157-163
[7]   TRACKING THE MOTION OF SKELETAL-MUSCLE WITH VELOCITY-ENCODED MR-IMAGING [J].
DRACE, JE ;
PELC, NJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06) :773-778
[8]   BRAIN MOTION - MEASUREMENT WITH PHASE-CONTRAST MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1992, 185 (03) :653-660
[9]   NORMAL FLOW PATTERNS OF INTRACRANIAL AND SPINAL CEREBROSPINAL-FLUID DEFINED WITH PHASE-CONTRAST CINE MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1991, 178 (02) :467-474
[10]  
KONDO C, 1991, AJR AM J ROENTGENOL, V157, P157