THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME

被引:113
作者
COOMBES, GM [1 ]
MILLARD, RJ [1 ]
机构
[1] UNIV NEW S WALES,SYDNEY,NSW,AUSTRALIA
关键词
ULTRASONOGRAPHY; BLADDER DISEASES; URINE; URINATION DISORDERS;
D O I
10.1016/S0022-5347(17)32314-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of 2 successive models of a portable (2.5 kg.) ultrasound unit in determining residual urine volumes in 100 patients was assessed. Ultrasound measurements were compared to post-scan bladder volumes obtained by catheterization and fluoroscopic screening in the same patients. The first ultrasound unit (group 1, 50 patients) showed correlation with residual volumes of 0.86 (R(2) = 0.73) and a mean difference from the true residual volume of 41 mi. (95% confidence interval 26 to 55 mi.). The second ultrasound unit (group 2, 50 patients) showed correlation with residual volumes of 0.97 (R(2) = 0.94) and a mean difference from the true residual volume of 24 mi. (95% confidence interval 17 to 31 mi.). The differences in volumes were significantly lower with scanner 2 (t = 2.02, p = 0.047). The mean difference between catheter volume estimate and true bladder volume was 25 mi. (95% confidence interval 16 to 34 mi.). The accuracy of the BladderScan BVI 2500+ scanner* is as good as catheter estimations of true residual volume and is sufficient to recommend its use as an alternative to catheterization for the determination of residual urine volume.
引用
收藏
页码:2083 / 2085
页数:3
相关论文
共 9 条
  • [1] CARDENAS DD, 1988, ARCH PHYS MED REHAB, V69, P514
  • [2] ACCURACY AND REPEATABILITY OF BLADDER VOLUME MEASUREMENT USING ULTRASONIC-IMAGING
    GRIFFITHS, CJ
    MURRAY, A
    RAMSDEN, PD
    [J]. JOURNAL OF UROLOGY, 1986, 136 (04) : 808 - 812
  • [3] THE ESTIMATION OF BLADDER VOLUME BY SONOCYSTOGRAPHY
    HAKENBERG, OW
    RYALL, RL
    LANGLOIS, SL
    MARSHALL, VR
    [J]. JOURNAL OF UROLOGY, 1983, 130 (02) : 249 - 251
  • [4] Harrison N, 1976, BRIT J UROL, V47, P805
  • [5] BLADDER VOLUME DETERMINATION USING A DEDICATED, PORTABLE ULTRASOUND SCANNER
    IRETON, RC
    KRIEGER, JN
    CARDENAS, DD
    WILLIAMSBURDEN, B
    KELLY, E
    SOUCI, T
    CHAPMAN, WH
    [J]. JOURNAL OF UROLOGY, 1990, 143 (05) : 909 - 911
  • [6] EXPERIENCE WITH PORTABLE ULTRASOUND EQUIPMENT AND MEASUREMENT OF URINE VOLUMES - INTER-USER RELIABILITY AND FACTORS OF PATIENT POSITION
    MASSAGLI, TL
    CARDENAS, DD
    KELLY, EW
    [J]. JOURNAL OF UROLOGY, 1989, 142 (04) : 969 - 971
  • [7] THE ACCURACY OF A HAND-HELD REAL-TIME ULTRASOUND SCANNER FOR ESTIMATING BLADDER VOLUME
    RAVICHANDRAN, G
    FELLOWS, GJ
    [J]. BRITISH JOURNAL OF UROLOGY, 1983, 55 (01): : 25 - 27
  • [8] DETERMINING RESIDUAL URINE VOLUMES USING A PORTABLE ULTRASONOGRAPHIC DEVICE
    REVORD, JP
    OPTIZ, JL
    MURTAUGH, P
    HARRISON, J
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1993, 74 (05): : 457 - 462
  • [9] THE ACCURACY OF A CATHETERIZED RESIDUAL URINE
    STOLLER, ML
    MILLARD, RJ
    [J]. JOURNAL OF UROLOGY, 1989, 141 (01) : 15 - 16