A ROUND-ROBIN PROGRAM ON INTERFACIAL TEST METHODS

被引:201
作者
PITKETHLY, MJ
FAVRE, JP
GAUR, U
JAKUBOWSKI, J
MUDRICH, SF
CALDWELL, DL
DRZAL, LT
NARDIN, M
WAGNER, HD
DILANDRO, L
HAMPE, A
ARMISTEAD, JP
DESAEGER, M
VERPOEST, I
机构
[1] OFF NATL ETUD & RECH AEROSP,PARIS,FRANCE
[2] TEXT RES INST,PRINCETON,NJ 08542
[3] DOW CHEM CO USA,MIDLAND,MI 48674
[4] DOW CHEM CO USA,FREEPORT,TX 77541
[5] MICHIGAN STATE UNIV,E LANSING,MI 48824
[6] CNRS,MULHOUSE,FRANCE
[7] WEIZMANN INST SCI,IL-76100 REHOVOT,ISRAEL
[8] POLITECN MILAN,I-20133 MILAN,ITALY
[9] BAM,BERLIN,GERMANY
[10] NRL,WASHINGTON,DC 20375
[11] CATHOLIC UNIV LEUVEN,B-3000 LOUVAIN,BELGIUM
关键词
COMPOSITES; INTERFACES; TESTS; FIBERS;
D O I
10.1016/0266-3538(93)90138-7
中图分类号
TB33 [复合材料];
学科分类号
摘要
A round-robin programme has been undertaken to assess the compatibility in the micromechanical techniques used to evaluate the interfacial shear strength of the fibre/matrix bond in composite materials. The tests selected for evaluation were the single-fibre pull-out test, the microdebond test, the fragmentation test and the micro-indentation test. Twelve laboratories were invited to participate in this programme. Each laboratory was supplied with Caurtaulds XA fibre in the untreated condition and with a standard surface treatment, and a quantity of epoxy resin, hardener and catalyst, all from the same batch. Some laboratories were supplied with composite bars made with the same materials. A common cure cycle was chosen for sample preparation. Each laboratory conducted the tests to its own procedures. The results showed that the scatter within each laboratory was acceptable but the scatter between laboratories for a particular test was high. The results are discussed and possible explanations are presented for these observations. The indications are that the fundamental procedures used in each laboratory are sound. The results also suggest that there is great potential for achieving standard procedures and reducing the inter-laboratory scatter. A further round-robin programme is proposed to generate test protocols.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 23 条
[11]  
Hampe A., 1988, AMTS MITTEILUNGSBLAT, V18, P3
[12]   TENSILE PROPERTIES OF FIBRE-REINFORCED METALS - COPPER/TUNGSTEN AND COPPER/MOLYBDENUM [J].
KELLY, A ;
TYSON, WR .
JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 1965, 13 (06) :329-&
[13]   MODELING OF CRITICAL FIBER LENGTH AND INTERFACIAL DEBONDING IN THE FRAGMENTATION TESTING OF POLYMER COMPOSITES [J].
LACROIX, T ;
TILMANS, B ;
KEUNINGS, R ;
DESAEGER, M ;
VERPOEST, I .
COMPOSITES SCIENCE AND TECHNOLOGY, 1992, 43 (04) :379-387
[14]  
Mandell J.F., 1980, INT J ADHES ADHES, V1, P40
[15]   MEASUREMENT AND MECHANICAL ASPECTS OF THE MICROBOND PULL-OUT TECHNIQUE FOR OBTAINING FIBER RESIN INTERFACIAL SHEAR-STRENGTH [J].
MILLER, B ;
GAUR, U ;
HIRT, DE .
COMPOSITES SCIENCE AND TECHNOLOGY, 1991, 42 (1-3) :207-219
[16]   AN ACOUSTIC-EMISSION TECHNIQUE FOR MEASURING FIBER FRAGMENT LENGTH DISTRIBUTIONS IN THE SINGLE-FIBER-COMPOSITE TEST [J].
NETRAVALI, AN ;
TOPOLESKI, LTT ;
SACHSE, WH ;
PHOENIX, SL .
COMPOSITES SCIENCE AND TECHNOLOGY, 1989, 35 (01) :13-29
[17]   CHARACTERIZING THE FIBER MATRIX INTERFACE OF CARBON FIBER-REINFORCED COMPOSITES USING A SINGLE FIBER PULL-OUT TEST [J].
PITKETHLY, MJ ;
DOBLE, JB .
COMPOSITES, 1990, 21 (05) :389-395
[18]   A DIRECT COMPARISON OF THE FRAGMENTATION TEST AND THE MICROBOND PULL-OUT TEST FOR DETERMINING THE INTERFACIAL SHEAR-STRENGTH [J].
RAO, V ;
HERRERAFRANCO, P ;
OZZELLO, AD ;
DRZAL, LT .
JOURNAL OF ADHESION, 1991, 34 (1-4) :65-77
[19]  
RJAN DS, 1989, J ACOUSTIC EMISSION, V8, P297
[20]  
Rouby D., 1990, Journal of Acoustic Emission, V9, P117