INFLUENCE OF INTERNAL CURRENT AND PACING CURRENT ON PACEMAKER LONGEVITY

被引:15
作者
SCHUCHERT, A
KUCK, KH
机构
[1] Medical Clinic, Department of Cardiology, University-Hospital Eppendurf, Hamburg
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1994年 / 17卷 / 01期
关键词
PACEMAKER PROGRAMMING; BATTERY CURRENT; INTERNAL AND PACING CURRENT; PACEMAKER BATTERY CAPACITY;
D O I
10.1111/j.1540-8159.1994.tb01344.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The effects of lower pulse amplitude on battery current and pacemaker longevity were studied comparing the new, small-sized VVI pacemaker, Minix 8341, with the former model, Pasys 8329. Battery current was telemetrically measured at 0.8, 1.6, 2.5, and 5.0 V pulse amplitude and 0.05, 0.25, 0.5, and 1.0 msec pulse duration. Internal current was assumed to be equal to the battery current at 0.8 V and 0.05 msec. Pacing current was calculated subtracting internal current from battery current. The Minix pacemaker had a significantly lower battery current because of a lower internal current (Minix: 4.1 +/- 0.1 mu A; Pasys: 16.1 +/- 0.1 mu A); pacing current of both units was similar. At 0.5 msec pulse duration, the programming from 5.0-2.5 V pulse amplitude resulted in a greater relative reduction of battery current in the newer pacemaker (51 % vs 25 %). Projected longevity of each pacemaker was 7.9 years at 5.0 V and 0.5 msec. The programming from 5.0-2.5 V extended the projected longevity by 2.3 years (Pasys) and by 7.1 years (Minix). Th e longevity was negligibly longer after programming to 1.6 V. Conclusion: Extension of pacemaker longevity can be achieved with the programming to 2.5 V or less if the connected pacemakers need a low internal current for their circuitry.
引用
收藏
页码:13 / 16
页数:4
相关论文
共 16 条
[1]  
[Anonymous], 1986, TECHNICAL MANUAL
[2]   PACEMAKER LONGEVITY [J].
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09) :1437-1438
[3]  
IRNICH W, 1989, HERZSCHRITTMACHER, V9, P164
[4]   ENERGY-CONSERVING PROGRAMMING OF VVI PACEMAKERS - A TELEMETRY-SUPPORTED, LONG-TERM, FOLLOW-UP-STUDY [J].
KLEIN, HH ;
KNAKE, W .
CLINICAL CARDIOLOGY, 1990, 13 (06) :409-413
[5]  
KLEIN HH, 1989, PACE, V13, P134
[6]   ACUTE AND LONG-TERM ATRIAL AND VENTRICULAR STIMULATION THRESHOLDS WITH A STEROID-ELUTING ELECTRODE [J].
KRUSE, IM ;
TERPSTRA, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (01) :45-49
[7]  
LEGERGREN H, 1966, ACTA CHIR SCAND, V132, P663
[8]   A COMPARISON OF PLATINIZED GROOVED ELECTRODE PERFORMANCE WITH RING-TIP ELECTRODES [J].
MIDEI, MG ;
JONES, BR ;
BRINKER, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (05) :752-756
[9]  
MULLER C, 1988, EUR HEART J, V9, P1003
[10]   THE PRESENT STATUS OF PROGRAMMABLE PACEMAKERS [J].
PARSONNET, V ;
RODGERS, T .
PROGRESS IN CARDIOVASCULAR DISEASES, 1981, 23 (06) :401-420