A SYSTEM MODEL FOR CLOSED-CIRCUIT INHALATION ANESTHESIA .1. COMPUTER STUDY

被引:32
作者
LEROU, JGC
DIRKSEN, R
KOLMER, HHB
BOOIJ, LHDJ
机构
[1] University of Nijmegen, Institute for Anesthesiology, 6500 HB Nijmegen
关键词
ANESTHETIC TECHNIQUES; CLOSED-CIRCUIT; ANESTHETIC GASES; NITROUS OXIDE; ANESTHETICS; VOLATILE; ISOFLURANE; ENFLURANE; COMPUTER; SIMULATION; MODELS; PROGRAMMING LANGUAGES; PHARMACOKINETICS; UPTAKE; DISTRIBUTION;
D O I
10.1097/00000542-199108000-00025
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Developing a custom computer program to simulate the uptake, distribution, and elimination of inhalational anesthetics allows the anesthesiologist to address specific problems, but extensive skills are required to translate the involved processes first into a set of mathematical equations and then into a satisfactory computer program. The first step is often facilitated by solutions offered in the literature. The second step demands computer proficiency that is often not available, but this problem can be obviated by means of a special-purpose simulation language (SPSL). We therefore constructed a model for closed-circuit inhalation anesthesia with the aid of the block-structured SPSL TUTSIM(R). Noticeable differences with previous models are that the linear, 14-compartment basic model does not assume a constant alveolar concentration and mimics circulation times through the use of blood pools. Advanced features of the SPSL were used to develop variants of the basic model to simulate feedback-controlled isoflurane administration, nitrous oxide uptake, and the impact of a nonlinearity by incorporating the effect of enflurane on cardiac output. Two variants were concatenated to form a multiple model showing the concentration and second-gas effects. The model was capable of reproducing the anesthetic uptake from previous experimental studies for nitrous oxide. After its validation for other anesthetic agents, the model can be used for clinical, teaching, and research purposes. The SPSL freed the authors from the problems associated with computer programming and allowed them to concentrate on the structure of the model.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 35 条
[11]  
EGER EI, 1974, ANESTHETIC UPTAKE AC, P80
[12]  
EGER EI, 1974, ANESTHETIC UPTAKE AC, P88
[13]  
EGER EI, 1985, NITROUS OXIDE, P86
[14]   INTERACTIONS AMONG VENTILATION, THE CIRCULATION, AND THE UPTAKE AND DISTRIBUTION OF HALOTHANE - USE OF A HYBRID COMPUTER MULTIPLE MODEL .1. THE BASIC MODEL [J].
FUKUI, Y ;
SMITH, NT .
ANESTHESIOLOGY, 1981, 54 (02) :107-118
[15]   PHARMACOKINETIC MODEL OF CLOSED-CIRCUIT INHALATION ANESTHESIA [J].
GOLDBERG, IS ;
MOSTERT, JW ;
LANZL, EF ;
LOWE, HJ .
ANNALS OF BIOMEDICAL ENGINEERING, 1978, 6 (03) :231-249
[16]  
HEFFERNAN PB, 1982, ANAESTHESIA, V37, P9, DOI 10.1111/j.1365-2044.1982.tb00986.x
[17]  
KETY SS, 1951, PHARMACOL REV, V3, P1
[18]   A SYSTEM MODEL FOR CLOSED-CIRCUIT INHALATION ANESTHESIA .2. CLINICAL VALIDATION [J].
LEROU, JGC ;
DIRKSEN, R ;
KOLMER, HHB ;
BOOIJ, LHDJ ;
BORM, GF .
ANESTHESIOLOGY, 1991, 75 (02) :230-237
[19]  
LOWE HJ, 1972, DOSE REGULATED PENTH
[20]  
LOWE HJ, 1979, LOW FLOW CLOSED SYST, P11