CHIRAL ANALYSIS OF METHADONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:57
作者
BECK, O
BOREUS, LO
LAFOLIE, P
JACOBSSON, G
机构
[1] Department of Clinical Pharmacology, Karolinska Hospital, S-10401 Stockholm
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 570卷 / 01期
关键词
D O I
10.1016/0378-4347(91)80216-Y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the chiral high-performance liquid chromatographic analysis of methadone in plasma has been developed. The method employed organic solvent extraction, enantiomeric separation on a Chiral AGP column, and ultraviolet absorption detection at 212 nm. The intra-day variation in the quantification of methadone enantiomers was less than 9% at the 100 ng/ml level, and the values obtained correlated well with those from a gas chromatographic-mass spectrometric method. Results from patients indicate inter-and intra-individual differences in the ratio between l- and d-methadone in plasma during therapy with racemic methadone. In one patient, a higher level of d-methadone in plasma was caused by both faster elimination and lower bioavailability of l-methadone.