DETERMINATION OF DIAMINOPYRENES AND AMINOPYRENES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION

被引:56
作者
HAYAKAWA, K
KITAMURA, R
BUTOH, M
IMAIZUMI, N
MIYAZAKI, M
机构
[1] Faculty of Pharmaceutical Sciences, Kanazawa University, Takara-machi
关键词
DIAMINOPYRENE; AMINOPYRENE; DINITROPYRENE; NITROPYRENE; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; PEROXYOXALATE-CHEMILUMINESCENCE DETECTION; CAR EMISSION SOOT;
D O I
10.2116/analsci.7.573
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high performance liquid chromatographic (HPLC) method with chemiluminescence (CL) detection was developed for the sensitive determination of 1,3-diaminopyrene (1,3-DAP), 1,6-DAP, 1,8-DAP and 1-aminopyrene (1-AP). The HPLC conditions were as follows: column, Cosmosil 5C18 (4.6 mm i.d. x 250 mm); mobile phase, 10 mM imidazole-perchloric acid buffer(pH 7.6)-acetonitrile (1:1, v/v); CL reagent, 0.02 mM bis(2,4,6-trichlorophenyl)oxalate (TCPO) and 15 mM hydrogen peroxide in acetonitrile. The oxidative degradation of DAPs and AP in the presence of metals was prevented by adding ascorbic acid to sample solutions. The calibration curves were straight over 2 orders of magnitude for all analytes, and their detection limits (as S/N was 3) were in the sub-fmol range. Dinitro- and nitropyrenes in sooty emissions of diesel- and gasoline-engine cars could be determined by this HPLC after reductive conversion into DAPs and AP, respectively, by refluxing the samples in the presence of sodium hydrosulfide.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 20 条
[1]  
CAMBELL RM, 1984, ANAL CHEM, V56, P1026
[2]   STOPPED-FLOW DETERMINATION OF THE PARAMETERS AFFECTING THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION [J].
HANAOKA, N ;
GIVENS, RS ;
SCHOWEN, RL ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2193-2197
[3]  
HASHIMOTO Y, 1984, CHEM PHARM BULL, V32, P1992
[4]  
HAYAKAWA K, 1989, J CHROMATOGR, V464, P343
[5]  
IMADA K, 1987, 3RD P INT C CARC MUT, P187
[6]   STUDIES ON THE EFFECTS OF IMIDAZOLE ON THE PEROXYOXALATE CHEMILUMINESCENCE DETECTION SYSTEM FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMAI, K ;
NISHITANI, A ;
TSUKAMOTO, Y ;
WANG, WH ;
KANDA, S ;
HAYAKAWA, K ;
MIYAZAKI, M .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (03) :100-104
[7]   STABILITY OF BIS(2,4,6-TRICHLOROPHENYL) OXALATE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR CHEMI-LUMINESCENCE DETECTION [J].
IMAIZUMI, N ;
HAYAKAWA, K ;
MIYAZAKI, M ;
IMAI, K .
ANALYST, 1989, 114 (02) :161-164
[8]   DETERMINATION OF NITRATED PYRENES AND THEIR DERIVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION AFTER ONLINE ELECTROCHEMICAL REDUCTION [J].
IMAIZUMI, N ;
HAYAKAWA, K ;
SUZUKI, Y ;
MIYAZAKI, M .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (03) :108-112
[9]   RELATIONSHIP BETWEEN POLAROGRAPHIC-REDUCTION POTENTIAL AND MUTAGENICITY OF NITROARENES [J].
KLOPMAN, G ;
TONUCCI, DA ;
HOLLOWAY, M ;
ROSENKRANZ, HS .
MUTATION RESEARCH, 1984, 126 (02) :139-144
[10]   DETERMINATION OF FLUORESCENT COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMI-LUMINESCENCE DETECTION [J].
KOBAYASHI, S ;
IMAI, K .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :424-427