HYDROGEN BACKGROUND IN TOTAL-BODY NITROGEN ESTIMATIONS

被引:10
作者
HUMPHRIES, IRJ
ALLEN, BJ
BLAGOJEVIC, N
GASKIN, KJ
机构
[1] ST GEORGE CANC CARE CTR,KOGARAH,NSW,AUSTRALIA
[2] AUSTRALIAN NUCL SCI & TECHNOL ORG,SUTHERLAND,NSW,AUSTRALIA
关键词
D O I
10.1088/0031-9155/40/1/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total body nitrogen (TBN) is measured by in vivo prompt gamma neutron capture analysis. Usually the background under the nitrogen peak is subtracted before calculating TEN from the ratio of nitrogen counts (at 10.8 MeV) to hydrogen counts (at 2.2 MeV). The hydrogen acts as an internal standard. The background under the hydrogen peak is usually ignored. The current study was undertaken to measure the variation of the hydrogen background (HB) in patients of different sizes and to determine whether the accuracy of TBN measurements is improved when an HB correction is incorporated. Heavy-water (D2O) phantoms were used to quantify patient HB. D2O simulates patient neutron scattering without contributing to the hydrogen peak. Equations were developed to predict HB in patient measurements. HB was found to vary from 9% of total counts for a 99 kg subject to 19% for a 7 kg infant. It was demonstrated that the accuracy of TBN measurements is improved for child-sized anthropometric phantoms of known composition when an HB correction is incorporated.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 12 条
  • [1] ALLEN BJ, 1987, IN VIVO BODY COMPOSI
  • [2] A TOTAL-BODY NITROGEN FACILITY FOR PEDIATRIC USE
    BAUR, LA
    ALLEN, BJ
    ROSE, A
    BLAGOJEVIC, N
    GASKIN, KJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (10) : 1363 - 1375
  • [3] NITROGEN DEPOSITION IN MALNOURISHED CHILDREN WITH CYSTIC-FIBROSIS
    BAUR, LA
    WATERS, DL
    ALLEN, BJ
    BLAGOJEVIC, N
    GASKIN, KJ
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 53 (02) : 503 - 511
  • [4] BAUR LA, 1993, COMMUNICATION
  • [5] A PROMPT GAMMA INVIVO NEUTRON-ACTIVATION ANALYSIS FACILITY FOR MEASUREMENT OF TOTAL-BODY NITROGEN IN THE CRITICALLY ILL
    BEDDOE, AH
    ZUIDMEER, H
    HILL, GL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (04) : 371 - 383
  • [6] EVALUATION OF AN INVIVO PROMPT GAMMA NEUTRON-ACTIVATION FACILITY FOR BODY-COMPOSITION STUDIES IN CRITICALLY ILL INTENSIVE-CARE PATIENTS - RESULTS ON 41 NORMALS
    BEDDOE, AH
    STREAT, SJ
    HILL, GL
    [J]. METABOLISM-CLINICAL AND EXPERIMENTAL, 1984, 33 (03): : 270 - 280
  • [7] DETERMINATION OF NITROGEN IN LIVING PATIENTS
    BIGGIN, HC
    CHAMBERL.MJ
    CHEN, NS
    FREMLIN, JH
    NOWOTNY, R
    MORGAN, WD
    ETTINGER, KV
    [J]. NATURE-NEW BIOLOGY, 1972, 236 (67): : 187 - &
  • [8] GASKIN KJ, 1990, ADV IN VIVO BODY COM
  • [9] IMPROVED CLINICAL FACILITY FOR INVIVO NITROGEN MEASUREMENT
    KRISHNAN, SS
    MCNEILL, KG
    MERNAGH, JR
    BAYLEY, AJ
    HARRISON, JE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04) : 489 - 499
  • [10] CALIBRATION OF A PROMPT NEUTRON-ACTIVATION ANALYSIS FACILITY FOR THE MEASUREMENT OF TOTAL-BODY PROTEIN
    MACKIE, A
    COWEN, S
    HANNAN, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (05) : 613 - 624