THE PELVIS - T2-WEIGHTED FAST SPIN-ECHO MR-IMAGING

被引:63
作者
NGHIEM, HV
HERFKENS, RJ
FRANCIS, IR
SOMMER, FG
JEFFREY, RB
LI, KCP
STEINER, RM
GLOVER, GH
机构
[1] STANFORD UNIV,MED CTR,DEPT RADIOL,300 PASTEUR DR,STANFORD,CA 94305
[2] UNIV MICHIGAN HOSP,DEPT DIAGNOST RADIOL & IMAGING,ANN ARBOR,MI 48109
[3] THOMAS JEFFERSON UNIV,DEPT RADIOL,PHILADELPHIA,PA 19107
关键词
MAGNETIC RESONANCE (MR); RAPID IMAGING; PELVIC ORGANS; MR; PELVIS;
D O I
10.1148/radiology.185.1.1523311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast spin-echo (SE) T2-weighted magnetic resonance (MR) imaging provides images with highly T2-weighted contrast in substantially reduced imaging times. In a prospective evaluation, fast SE T2-weighted imaging of the pelvis was compared with conventional SE T2-weighted imaging in 30 consecutive patients in whom pelvic pathologic conditions were suspected. Three reviewers independently analyzed the images for (a) overall image quality, (b) pelvic organ definition, (c) conspicuity of pelvic fluid, and (d) conspicuity of pelvic pathologic conditions. Fast SE images were rated superior to conventional SE T2-weighted images in 60% (54 of 90) of the case reviews for overall image quality, in 69% (62 of 90) for pelvic organ definition, in 63% (57 of 90) for conspicuity of pelvic fluid, and in 68% (43 of 63) for conspicuity of pelvic pathologic conditions. The fast SE examinations were typically three to four times faster than conventional SE T2-weighted examinations. No pathologic findings seen on conventional SE T2-weighted images were undetected on fast SE images. Fast SE images may replace conventional SE T2-weighted images in MR imaging of the pelvis.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 14 条
  • [1] PROSTATIC-CARCINOMA - STAGING WITH MR IMAGING AT 1.5-T
    BEZZI, M
    KRESSEL, HY
    ALLEN, KS
    SCHIEBLER, ML
    ALTMAN, HG
    WEIN, AJ
    POLLACK, HM
    [J]. RADIOLOGY, 1988, 169 (02) : 339 - 346
  • [2] THE ABNORMAL PROSTATE - MR IMAGING AT 1.5 T WITH HISTOPATHOLOGIC CORRELATION
    CARROL, CL
    SOMMER, FG
    MCNEAL, JE
    STAMEY, TA
    [J]. RADIOLOGY, 1987, 163 (02) : 521 - 525
  • [3] 3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION
    GLOVER, GH
    SCHNEIDER, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 371 - 383
  • [4] GLOVER GH, 1991, RADIOLOGY, V181, P142
  • [5] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833
  • [6] MRI OF THE FEMALE PELVIS - A REVIEW
    HRICAK, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (06) : 1115 - 1122
  • [7] INVASIVE CERVICAL-CARCINOMA - COMPARISON OF MR IMAGING AND SURGICAL FINDINGS
    HRICAK, H
    LACEY, CG
    SANDLES, LG
    CHANG, YCF
    WINKLER, ML
    STERN, JL
    [J]. RADIOLOGY, 1988, 166 (03) : 623 - 631
  • [8] COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES
    MELKI, PS
    MULKERN, RV
    PANYCH, LP
    JOLESZ, FA
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03): : 319 - 326
  • [9] SIMULTANEOUS SPATIAL AND SPECTRAL SELECTIVE EXCITATION
    MEYER, CH
    PAULY, JM
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (02) : 287 - 304
  • [10] CONTRAST MANIPULATION AND ARTIFACT ASSESSMENT OF 2D AND 3D RARE SEQUENCES
    MULKERN, RV
    WONG, STS
    WINALSKI, C
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 557 - 566