EFFECT OF COLLOIDAL STABILITY OF CERAMIC SUSPENSIONS ON NEBULIZATION OF SLURRIES FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY

被引:40
作者
FARINAS, JC [1 ]
MORENO, R [1 ]
MERMET, JM [1 ]
机构
[1] UNIV LYON 1,SCI ANALYT LAB,F-69622 VILLEURBANNE,FRANCE
关键词
INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; SIGNAL ENHANCEMENT; SLURRY NEBULIZATION; CERAMIC SUSPENSION; COLLOIDAL STABILITY;
D O I
10.1039/ja9940900841
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The direct solid analysis of ceramic powders can be carried out by inductively coupled plasma atomic emission spectrometry (ICP-AES) using slurry sample introduction. However, a highly stable suspension is needed in order to obtain a representative aerosol for introduction into the ICP. In this work, the importance of the effect of the rheology and the stability of the ceramic suspensions on the analytical results provided by slurry nebulization ICP-AES is demonstrated. The basic concepts involved in the stabilization and homogenization of ceramic slurries are discussed. A general overview of the stabilizing mechanisms (electrostatic, steric and electrosteric) and the role of the different stabilizing additives, and the most adequate use of them, is described. Alumina (Al2O3) slurries, as a case study, are discussed. The rheological parameters, such as zeta potential, viscosity and sedimentation have been studied by changing the pH of the slurry and by introducing different dispersing additives (Dolapix PC-33, Darvan-7, Darvan-C, sodium hexametaphosphate, glycerol plus Kodak photoflow, Triton X-100 and Produkt PKV-5088). Their effect on stability is discussed, as well as the relationship between the stability of the slurry and the intensity and precision of the measurements provided by ICP-AES. It is clearly demonstrated that higher intensities and lower relative standard deviation values are obtained for a well-dispersed, stable slurry.
引用
收藏
页码:841 / 849
页数:9
相关论文
共 52 条
[1]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .8. FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
AMBROSE, AJ ;
EBDON, L ;
FOULKES, ME ;
JONES, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (02) :219-222
[2]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[3]   RAPID SLURRY ANALYSIS OF SOLID COAL AND FLY-ASH SAMPLES [J].
BRADSHAW, D ;
SLAVIN, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (12) :1245-1256
[4]   A STUDY OF SOME TECHNIQUES FOR DIRECT SOLIDS SAMPLING IN PLASMA SPECTROMETRY [J].
BROEKAERT, JAC ;
LEIS, F ;
RAEYMAEKERS, B ;
ZARAY, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (4-5) :339-353
[5]   A STUDY OF LASER ABLATION AND SLURRY NEBULIZATION SAMPLE INTRODUCTION FOR THE ANALYSIS OF GEOCHEMICAL MATERIALS BY INDUCTIVELY COUPLED PLASMA SPECTROMETRY [J].
DARKE, SA ;
LONG, SE ;
PICKFORD, CJ ;
TYSON, JF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03) :284-289
[6]   DIRECT DETERMINATION OF IMPURITIES IN POWDERED SILICON-CARBIDE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING THE SLURRY SAMPLING TECHNIQUE [J].
DOCEKAL, B ;
KRIVAN, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :521-528
[8]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .7. ANALYSIS OF COAL USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EBDON, L ;
FOULKES, ME ;
PARRY, HGM ;
TYE, CT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :753-761
[9]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .5. ANALYSIS OF KAOLIN USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
EBDON, L ;
COLLIER, AR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :557-561