COMPARISON OF DUAL PHOTON AND DUAL ENERGY X-RAY BONE DENSITOMETERS IN A CLINIC SETTING

被引:10
作者
NELSON, DA
BROWN, EB
FLYNN, MJ
CODY, DD
SHAFFER, S
机构
[1] HENRY FORD HOSP,DIV BIOSTAT & RES EPIDEMIOL,DETROIT,MI 48202
[2] HENRY FORD HOSP,DIV RADIOL PHYS,DETROIT,MI 48202
关键词
DUAL PHOTON ABSORPTIOMETRY; DUAL ENERGY X-RAY ABSORPTIOMETRY; PRECISION;
D O I
10.1007/BF01106090
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In clinical practice, decisions must be made about whether and how to convert to newer technologies. To address this issue, two separate studies were conducted. We evaluated the relationships between results of lumbar spine measurements using two dual photon absorptiometry (DPA1 and DPA2) instruments and one dual energy X-ray (DXA) instrument with the same subjects (49 volunteers), and also in 65 patients who were measured on the DPA1 and DXA machines. Second, we measured the lumbar spine and the proximal femur in three groups of 12 female volunteers three times on one instrument within 1 week. We purposely simulated a busy clinic setting with different technologists, older radioactive sources, and a heterogeneous patient group. The comparison study indicated a significant difference between the mean bone density values reported by the machines, but the results were highly correlated (R2 = 0.89-0.96). The short-term precision errors (coefficients of variation) differed among the instruments, ranging from 1.3% (DXA of the spine) to 5.1% (DPA1 of the spine), and in the femoral neck, 2.3% and 2.4% (DXA and DPA1, respectively) versus 3.5% by DPA2. This study emphasizes the differences between instruments, the potential for greater error in busy clinic environments, and the apparent superiority of dual energy X-ray absorptiometry under these less than ideal conditions.
引用
收藏
页码:591 / 595
页数:5
相关论文
共 17 条
[1]   QUANTITATIVE DUAL-ENERGY RADIOGRAPHIC ABSORPTIOMETRY OF THE LUMBAR SPINE - INVIVO COMPARISON WITH DUAL-PHOTON ABSORPTIOMETRY [J].
BORDERS, J ;
KERR, E ;
SARTORIS, DJ ;
STEIN, JA ;
RAMOS, E ;
MOSCONA, AA ;
RESNICK, D .
RADIOLOGY, 1989, 170 (01) :129-131
[2]   COMPARATIVE-ASSESSMENT OF DUAL-PHOTON ABSORPTIOMETRY AND DUAL-ENERGY RADIOGRAPHY [J].
GLUER, CC ;
STEIGER, P ;
SELVIDGE, R ;
ELLIESENKLIEFOTH, K ;
HAYASHI, C ;
GENANT, HK .
RADIOLOGY, 1990, 174 (01) :223-228
[3]   VALIDITY OF DUAL-PHOTON ABSORPTIOMETRY [J].
GLUER, CC ;
STEIGER, P ;
GENANT, HK .
RADIOLOGY, 1988, 166 (02) :574-575
[4]   DUAL-ENERGY RADIOGRAPHIC ABSORPTIOMETRY OF THE LUMBAR SPINE - CLINICAL-EXPERIENCE WITH 2 DIFFERENT SYSTEMS [J].
GUNDRY, CR ;
MILLER, CW ;
RAMOS, E ;
MOSCONA, A ;
STEIN, JA ;
MAZESS, RB ;
SARTORIS, DJ ;
RESNICK, D .
RADIOLOGY, 1990, 174 (02) :539-541
[5]   QUANTITATIVE DIGITAL RADIOGRAPHY VERSUS DUAL PHOTON-ABSORPTIOMETRY OF THE LUMBAR SPINE [J].
KELLY, TL ;
SLOVIK, DM ;
SCHOENFELD, DA ;
NEER, RM .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1988, 67 (04) :839-844
[6]   PERFORMANCE EVALUATION OF A DUAL-ENERGY X-RAY BONE DENSITOMETER [J].
MAZESS, R ;
COLLICK, B ;
TREMPE, J ;
BARDEN, H ;
HANSON, J .
CALCIFIED TISSUE INTERNATIONAL, 1989, 44 (03) :228-232
[7]  
MAZESS RB, 1989, P SOC EXP BIOL MED, V191, P261
[8]  
NILAS L, 1988, BONE MINER, V3, P305
[9]   AXIAL BONE-DENSITY IN RHEUMATOID-ARTHRITIS - COMPARISON OF DUAL-ENERGY PROJECTION RADIOGRAPHY AND DUAL-PHOTON ABSORPTIOMETRY [J].
OMALLEY, M ;
KENRICK, AJ ;
SARTORIS, DJ ;
HOCHBERG, AM ;
WEISMAN, MH ;
RAMOS, E ;
ZVAIFLER, N ;
RESNICK, D .
RADIOLOGY, 1989, 170 (02) :501-505
[10]   DUAL ENERGY RADIOGRAPHY (DER) - A PRELIMINARY COMPARATIVE-STUDY [J].
PACIFICI, R ;
RUPICH, R ;
VERED, I ;
FISCHER, KC ;
GRIFFIN, M ;
SUSMAN, N ;
AVIOLI, LV .
CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (03) :189-191