FETAL CROWN-RUMP LENGTH - REEVALUATION OF RELATION TO MENSTRUAL AGE (5-18 WEEKS) WITH HIGH-RESOLUTION REAL-TIME US

被引:304
作者
HADLOCK, FP
SHAH, YP
KANON, DJ
LINDSEY, JV
机构
[1] Department of Radiology, Baylor College of Medicine, Houston, TX 77030
关键词
FETUS; GROWTH AND DEVELOPMENT; US;
D O I
10.1148/radiology.182.2.1732970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Because of recent challenges in the literature regarding the validity of the older crown-rump length (CRL) data developed with conventional static-image ultrasound scanners, the authors evaluated the relationship between CRL and menstrual age of fetuses in a population of 416 patients with good menstrual dates. By using a variety of commercially available transabdominal and transvaginal real-time ultrasound probes, the authors demonstrated that measurements can be made successfully for CRLs varying in size from 2 mm to 12 cm. Regression analysis of the data resulted in development of a new table for predicting menstrual age of fetuses on the basis of CRL measurements obtained between 5 and 18 weeks gestation. Although the magnitude of the raw residuals increased over time, the variability in predicting menstrual age was demonstrated to be relatively constant at +/- 8% (2 standard deviations) when expressed as a percentage of the predicted value. The accuracy in predicting menstrual age from CRL after 14 weeks was equivalent to but not better than conventional measurements such as biparietal diameter and femur length.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 22 条
  • [1] COMPARISON OF CROWN-RUMP LENGTH MEASUREMENTS USING A REAL-TIME SCANNER IN AN ANTENATAL CLINIC AND A CONVENTIONAL B-SCANNER
    ADAM, AH
    ROBINSON, HP
    DUNLOP, C
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1979, 86 (07): : 521 - 524
  • [2] ESTIMATION OF GESTATIONAL-AGE DURING THE 1ST TRIMESTER BY REAL-TIME MEASUREMENT OF FETAL CROWN-RUMP LENGTH AND BIPARIETAL DIAMETER
    BOVICELLI, L
    ORSINI, LF
    RIZZO, N
    CALDERONI, P
    PAZZAGLIA, FL
    MICHELACCI, L
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (02) : 71 - 75
  • [3] CULLINAN JA, 1988, J ULTRAS MED, V7, pS108
  • [4] PREDICTION OF DELIVERY DATE BY ULTRASONIC MEASUREMENT OF FETAL CROWN-RUMP LENGTH
    DRUMM, JE
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1977, 84 (01): : 1 - 5
  • [5] ULTRASONIC MEASUREMENT OF FETAL CROWN-RUMP LENGTH AS A METHOD OF ASSESSING GESTATIONAL AGE
    DRUMM, JE
    CLINCH, J
    MACKENZIE, G
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1976, 83 (06): : 417 - 421
  • [6] FETAL CROWN-RUMP LENGTH VALUES IN THE 1ST TRIMESTER BASED UPON OVULATION TIMING USING THE LUTEINIZING-HORMONE SURGE
    EVANS, J
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (01): : 48 - 51
  • [7] GOLDSTEIN I, 1991, OBSTET GYNECOL, V77, P885
  • [8] CROWN-RUMP LENGTH MEASUREMENTS REVISITED
    KOORNSTRA, G
    WATTEL, E
    EXALTO, N
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1990, 35 (2-3): : 131 - 138
  • [9] KURJAK A, 1975, JCU, V4, P83
  • [10] LEOPOLD GR, 1986, J ULTRAS MED, V5, P241