VOLTAMMETRIC STUDY OF SALBUTAMOL, FENOTEROL AND METAPROTERENOL AT UNMODIFIED AND NAFION-MODIFIED CARBON-PASTE ELECTRODES

被引:48
作者
BOYD, D
RODRIGUEZ, JRB
ORDIERES, AJM
BLANCO, PT
SMYTH, MR
机构
[1] UNIV OVIEDO,DEPT PHY & ANALYT CHEM,E-33006 OVIEDO,SPAIN
[2] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
BETA-AGONIST DRUG; CARBON PASTE ELECTRODE; NAFION-MODIFIED ELECTRODE; CYCLIC VOLTAMMETRY;
D O I
10.1039/an9941901979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical study of three important beta-agonist drugs at unmodified and Nafion-modified carbon paste electrodes was carried out. All the compounds are oxidized irreversibly st high positive potentials at a bare carbon paste electrode, giving rise to sharp, well-defined peaks. A secondary oxidation process was observed at pH values above 6.0. The rate-determining step was investigated for each compound at two concentration levels. Electrochemical activation procedures were optimized to ensure reproducible signals for the construction of calibration graphs. The modification of the carbon paste surface with a Nafion film allowed a preconcentration process to take place for all compounds, such that higher sensitivities were achieved compared with the bare surface. Such modifications resulted in limits of detection for the compounds down to 2.5 X 10(-8) mol dm(-3). Optimum accumulation was obtained at low pH values (2-3). Cyclic voltammetry at two Nafion film thicknesses demonstrated that a diffusion-controlled process exists within the Nafion layer. Salbutamol showed a higher affinity for Nafion than the other two compounds, both in terms of longer linear accumulation and linear accumulation at higher concentrations.
引用
收藏
页码:1979 / 1984
页数:6
相关论文
共 22 条
[1]   COMPARISON OF ISOTACHOPHORESIS, CAPILLARY ZONE ELECTROPHORESIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF SALBUTAMOL, TERBUTALINE SULFATE AND FENOTEROL HYDROBROMIDE IN PHARMACEUTICAL DOSAGE FORMS [J].
ACKERMANS, MT ;
BECKERS, JL ;
EVERAERTS, FM ;
SEELEN, IGJA .
JOURNAL OF CHROMATOGRAPHY, 1992, 590 (02) :341-353
[2]  
ADAM A, 1990, J IMMUNOASSAY, V2, P329
[3]   DETERMINATION OF ALBUTEROL CONCENTRATIONS IN HUMAN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
BLAND, RE ;
TANNER, RJN ;
CHERN, WH ;
LANG, JR ;
POWELL, JR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (07) :591-596
[4]  
BOENISCH B, 1992, P EC WORKSHOP THESSA, P104
[5]   NAFION-COATED CARBON-FIBER ELECTRODES FOR NEUROCHEMICAL STUDIES IN BRAIN-TISSUE [J].
CAPELLA, P ;
GHASEMZADEH, B ;
MITCHELL, K ;
ADAMS, RN .
ELECTROANALYSIS, 1990, 2 (03) :175-182
[6]   DETERMINATION OF ALBUTEROL IN HUMAN-SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
EMM, T ;
LESKO, LJ ;
LESLIE, J ;
PERKAL, MB .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 427 (01) :188-194
[7]  
FURST P, 1989, DEUT LEBENSM-RUNDSCH, V85, P341
[8]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM ;
BATLEY, GE .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1608-1614
[9]  
HUILIANG H, 1988, ANAL CHIM ACTA, V207, P17
[10]  
KATZUNG BG, 1989, BASIC CLIN PHARM, P3