CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION

被引:220
作者
DAWANT, BM
ZIJDENBOS, AP
MARGOLIN, RA
机构
[1] VANDERBILT UNIV,DEPT PSYCHIAT,NASHVILLE,TN 37235
[2] VANDERBILT UNIV,DEPT RADIOL,NASHVILLE,TN 37235
关键词
D O I
10.1109/42.251128
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
A number of supervised and unsupervised pattern recognition techniques have been proposed in recent years for the segmentation and the quantitative analysis of MR images. However, the efficacy of these techniques is affected by acquisition artifacts such as inter-slice, intra-slice, and inter-patient intensity variations. In this paper a new approach to the correction of intra-slice intensity variations is presented. Results demonstrate that the correction process enhances the performance of backpropagation neural network classifiers designed for the segmentation of the images. Two slightly different versions of the method are presented. The first version fits an intensity correction surface directly to reference points selected by the user in the images. The second version fits the surface to reference points obtained by an intermediate classification operation. Qualitative and quantitative evaluation of both methods reveals that the first one leads to a better correction of the images than the second but that it is more sensitive to operator errors.
引用
收藏
页码:770 / 781
页数:12
相关论文
共 27 条
[1]
OPTIMIZATION NEURAL NETWORKS FOR THE SEGMENTATION OF MAGNETIC-RESONANCE IMAGES [J].
AMARTUR, SC ;
PIRAINO, D ;
TAKEFUJI, Y .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :215-220
[2]
[Anonymous], 1986, NUMERICAL RECIPES
[3]
TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[4]
CORRECTION FOR INTENSITY FALLOFF IN SURFACE COIL MAGNETIC-RESONANCE IMAGING [J].
BREY, WW ;
NARAYANA, PA .
MEDICAL PHYSICS, 1988, 15 (02) :241-245
[5]
DUCHON J, 1976, REV FR AUTOMAT INFOR, V10, P5
[6]
DUCHON J, 1975, 231 U GREN REP
[7]
SCATTERED DATA INTERPOLATION - TESTS OF SOME METHODS [J].
FRANKE, R .
MATHEMATICS OF COMPUTATION, 1982, 38 (157) :181-200
[8]
VOLUMETRIC MEASUREMENT OF CANINE GLIOMAS USING MRI [J].
GALLOWAY, RL ;
MACIUNAS, RJ ;
FAILINGER, AL ;
WHELAN, HT .
MAGNETIC RESONANCE IMAGING, 1990, 8 (02) :161-165
[9]
UNSUPERVISED TISSUE-TYPE SEGMENTATION OF 3D DUAL-ECHO MR HEAD DATA [J].
GERIG, G ;
MARTIN, J ;
KIKINIS, R ;
KUBLER, O ;
SHENTON, M ;
JOLESZ, FA .
IMAGE AND VISION COMPUTING, 1992, 10 (06) :349-360
[10]
NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232