PERFORMANCE OF QPET, A HIGH-RESOLUTION 3D PET IMAGING-SYSTEM FOR SMALL VOLUMES

被引:12
作者
MCKEE, BTA
DICKSON, AW
HOWSE, DC
机构
[1] QUEENS UNIV,DEPT MED,KINGSTON K7L 3N6,ONTARIO,CANADA
[2] QUEENS UNIV,DEPT PHYS,KINGSTON K7L 3N6,ONTARIO,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/42.276156
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
QPET is a positron imaging system developed at Queen's University for high-resolution, 3D imaging of small volumes; it includes a pair of planar gamma-ray detectors 25.4 cm square, which rotate about a central axis with a quasi-cylindrical geometry. We describe here the performance of this system. Basic characteristics of the detectors are evaluated: a spatial sampling of 1 mm, a quantum efficiency of 9.3% (for 511 keV gamma rays with normal incidence), and a time resolution of 88 ns. Models are developed to characterize the system deadtime and the sensitivity in terms of the noise-equivalent counting rate. With an 8 cm diameter spherical source, the noise-equivalent counting rate reaches a maximum at just over 3 kcps for an activity concentration of 2 muCi/cc; the random coincidence events and the deadtime losses both contribute significantly and the scatter contribution is small. Spatial resolution and uniformity over the field of view are evaluated by imaging short and long line sources; a spatial resolution of 2.7 mm in the transverse directions and 2.0 mm in the axial direction is achieved, with excellent uniformity throughout the field of view. The detector response is amplitude invariant across a 20 cm transverse diameter and a 9 cm axial length with the acceptance angle limited to +/-25-degrees in the axial direction. As an example of the imaging capabilities of QPET, we show 3D images of F-18 uptake in the bones of a rat, showing the excellent spatial resolution. This system is best suited to limited-volume applications where high counting rates are not necessary, but where high spatial resolution and uniform detector response are priorities.
引用
收藏
页码:176 / 185
页数:10
相关论文
共 30 条
[1]   OBJECT SHAPE DEPENDENT SCATTER SIMULATIONS FOR PET [J].
BARNEY, JS ;
ROGERS, JG ;
HARROP, R ;
HOVERATH, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :719-725
[2]   IMAGE QUANTIFICATION WITH A LARGE AREA MULTIWIRE PROPORTIONAL CHAMBER POSITRON CAMERA (MUP-PET) [J].
CHERRY, SR ;
MARSDEN, PK ;
OTT, RJ ;
FLOWER, MA ;
WEBB, S ;
BABICH, JW .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :694-700
[3]   INCREASED SENSITIVITY AND FIELD OF VIEW FOR A ROTATING POSITRON CAMERA [J].
CLACK, R ;
TOWNSEND, D ;
JEAVONS, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1421-1431
[4]  
DERENZO SE, 1980, J NUCL MED, V21, P971
[5]  
DICKSON AW, 1991, THESIS U KINGSTON ON
[6]   DETECTOR, SHIELDING AND GEOMETRIC DESIGN FACTORS FOR A HIGH-RESOLUTION PET SYSTEM [J].
DIGBY, WM ;
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :664-670
[7]   PROPORTIONAL CHAMBERS FOR VERY HIGH COUNTING RATES BASED ON GAS-MIXTURES OF CF4 WITH HYDROCARBONS [J].
FISCHER, J ;
HRISOHO, A ;
RADEKA, V ;
REHAK, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (2-3) :249-264
[8]   REMOVING THE INTERFERENCE ERROR BETWEEN ATTENUATION CORRECTION AND SCATTER SUBTRACTION IN 3D PET IMAGING [J].
HARVEY, PJ ;
HOWSE, DC ;
MCKEE, BTA .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03) :767-777
[9]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[10]   IMAGE-RECONSTRUCTION FOR A 3D PET SYSTEM USING A MINIMUM NORM CONSTRAINT [J].
HOGAN, MJ ;
HARVEY, PJ ;
HOWSE, DC ;
MCKEE, BTA .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :35-46