INDIUM-TIN OXIDE FILM ELECTRODE AS CATALYTIC AMPEROMETRIC SENSOR FOR HYDROGEN-PEROXIDE

被引:35
作者
CAI, XH
OGOREVC, B
TAVCAR, G
WANG, J
机构
[1] NATL INST CHEM,ANALYT CHEM LAB,LJUBLJANA 61115,SLOVENIA
[2] NEW MEXICO STATE UNIV,DEPT CHEM,LAS CRUCES,NM 88003
关键词
ELECTROCHEMICAL SENSOR; THIN FILM; AMPEROMETRIC DETECTION; HYDROGEN PEROXIDE; INDIUM-TIN OXIDE;
D O I
10.1039/an9952002579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A commercial indium-tin oxide (ITO) film, deposited on a glass substrate, was investigated for its potential use as a disposable amperometric sensor for hydrogen peroxide determination in aqueous solutions, After a very simple; yet crucial, electrochemical pre-treatment of a fresh ITO film electrode, a stable and sensitive electrocatalytic response to hydrogen peroxide was exhibited, The electrocatalytic character and factors influencing hydrodynamic amperometric performance of the ITO film electrode mere examined and discussed. Under optimized conditions, the amperometric signal was linearly proportional to the hydrogen peroxide concentration over the range 8.4 x 10(-5)-2.1 x 10(-3) mol l(-1) (2.9-71.4 mg l(-1)) with a detection limit of 5.6 x 10(-1) mol l(-5) mol l(-1) (1.9 mg l(-1)), The electrode also displayed good reproducibility with an s(r) value of 1.5% for 20 consecutive chronoamperometric measurements of 2.8 x 10(-4) mol l(-1) hydrogen peroxide.
引用
收藏
页码:2579 / 2583
页数:5
相关论文
共 29 条
[1]  
BOND AM, 1980, MODERN POLAROGRAPHIC, P190
[2]   PREPARATION OF CONDUCTING AND TRANSPARENT THIN-FILMS OF TIN-DOPED INDIUM OXIDE BY MAGNETRON SPUTTERING [J].
BUCHANAN, M ;
WEBB, JB ;
WILLIAMS, DF .
APPLIED PHYSICS LETTERS, 1980, 37 (02) :213-215
[3]   ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE ON A PALLADIUM-MODIFIED CARBON-PASTE ELECTRODE [J].
CAI, XH ;
KALCHER, K ;
KOLBL, G ;
NEUHOLD, C ;
DIEWALD, W ;
OGOREVC, B .
ELECTROANALYSIS, 1995, 7 (04) :340-345
[4]   STUDIES ON THE ELECTROCATALYTIC REDUCTION OF ALIPHATIC-ALDEHYDES ON PALLADIUM-MODIFIED CARBON-PASTE ELECTRODES [J].
CAI, XH ;
KALCHER, K .
ELECTROANALYSIS, 1994, 6 (5-6) :397-404
[5]   ELECTROCHEMICAL INVESTIGATION OF ELECTROCHROMISM IN TRANSPARENT CONDUCTIVE OXIDES [J].
COGAN, SF ;
ANDERSON, EJ ;
PLANTE, TD ;
RAUH, RD .
APPLIED OPTICS, 1985, 24 (15) :2282-2283
[6]   ITO AS COUNTERELECTRODE IN A POLYMER BASED ELECTROCHROMIC DEVICE [J].
CORRADINI, A ;
MARINANGELI, AM ;
MASTRAGOSTINO, M .
ELECTROCHIMICA ACTA, 1990, 35 (11-12) :1757-1760
[7]   MECHANISM OF THE MEDIATED REDUCTION OF HYDROGEN-PEROXIDE AT AN ELECTRODE MODIFIED WITH A FILM CONTAINING A BASIC FORM OF IRIDIUM OXIDE [J].
COX, JA ;
JAWORSKI, RK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 281 (1-2) :163-170
[8]   VOLTAMMETRIC REDUCTION AND DETERMINATION OF HYDROGEN-PEROXIDE AT AN ELECTRODE MODIFIED WITH A FILM CONTAINING PALLADIUM AND IRIDIUM [J].
COX, JA ;
JAWORSKI, RK .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :2176-2178
[9]   ELECTROCHROMIC BEHAVIOR IN ITO AND RELATED OXIDES [J].
GOLDNER, RB ;
FOLEY, G ;
GOLDNER, EL ;
NORTON, P ;
WONG, K ;
HAAS, T ;
SEWARD, G ;
CHAPMAN, R .
APPLIED OPTICS, 1985, 24 (15) :2283-2284
[10]   STUDY OF THE CATALYTIC BEHAVIOR OF 2-BENZOYLPYRIDINE OXIME IN THE PRESENCE OF COBALT AND NITRATE IONS BY DIFFERENTIAL PULSE POLAROGRAPHY [J].
GOMEZNIETO, MA ;
DECASTRO, MDL ;
VALCARCEL, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 153 (1-2) :201-222