DETERMINATION OF OXYGEN-CONTAINING ADDITIVES IN GASOLINE BY GAS-CHROMATOGRAPHY MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY

被引:18
作者
GOODE, SR
THOMAS, CL
机构
关键词
OXYGEN-SELECTIVE DETECTION; GASOLINE ANALYSIS; MICROWAVE-INDUCED PLASMA; GAS-CHROMATOGRAPHIC DETECTOR; ATOMIC EMISSION SPECTROMETRY;
D O I
10.1039/ja9940900073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and characterization of a method for the determination of oxygen-containing (oxygenate species in a complex mixture of hydrocarbons is described. A microwave-induced plasma (MIP) atomic emission detector is coupled to a gas chromatograph, and atomic oxygen emission is monitored as an indication of oxygenated compounds in the gas chromatograph effluent. On-line helium purification and the use of a tangential-flow torch provide conditions ideal for oxygen-selective analysis without make-up gases or extensive background correction. Furthermore, large amounts of solvent or sample do not extinguish the plasma so samples can be analysed directly without dilution, addition of reagent gases or solvent venting procedures. Both axial and lateral viewing positions were investigated for analytical use. Detection limits for oxygen were 1 ng s-1 for both axial and lateral positions but sensitivity was higher in the axial position. However, selectivity over carbon in the lateral position was 4850:1 compared with 1 55: 1 in the axial position. The gas chromatography MIP method was applied, using lateral viewing, to the analysis of alcohols in National Institute of Standards and Technology (NIST) reference fuel standards and to commercial gasoline samples collected from Columbia, SC, USA and Greensboro, NC, USA. Experimental results of oxygen-selective analysis of NIST reference fuel are in good agreement with the certified values. Results obtained for the determination of oxygenated compounds in gasoline samples further demonstrate the usefulness of the method for the analysis of a complex mixture of hydrocarbons. Most spike recoveries were within 10% of the expected values. Examples of oxygen-selective chromatograms are presented to demonstrate the usefulness and selectivity of the method.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 20 条
[11]   EVALUATION OF A MICROWAVE CAVITY, DISCHARGE-TUBE, AND GAS-FLOW SYSTEM FOR COMBINED GAS-CHROMATOGRAPHY ATOMIC EMISSION DETECTION [J].
QUIMBY, BD ;
SULLIVAN, JJ .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1027-1034
[12]   AN IMPROVED BEENAKKER-TYPE CAVITY FOR MICROWAVE INDUCED PLASMA SPECTROMETRY [J].
RAIT, N ;
GOLIGHTLY, DW ;
MASSONI, CJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (07) :931-937
[13]   CONSIDERATION OF AN ATMOSPHERIC-PRESSURE MICROWAVE-INDUCED HELIUM PLASMA AS AN OXYGEN-SELECTIVE GAS-CHROMATOGRAPHIC DETECTOR [J].
SLATKAVITZ, KJ ;
UDEN, PC ;
BARNES, RM .
JOURNAL OF CHROMATOGRAPHY, 1986, 355 (01) :117-126
[14]  
THOMAS CL, 1993, UNPUB MAR PITTSB C A
[15]  
UNZELMAN GH, 1991, OIL GAS J 0415, P44
[16]  
VERGA GR, 1988, HRC-J HIGH RES CHROM, V11, P248
[17]  
WYLIE PL, 1989, HRC-J HIGH RES CHROM, V12, P813
[18]  
ZENG KW, 1985, SPECTROCHIM ACTA B, V40, P349
[19]  
1986, ALCOHOLS REFERE 0319, P2
[20]  
1992, ANN BOOK ASTM STANDA, P612