QUANTITATIVE VOLUME FLOW ESTIMATION USING VELOCITY PROFILES

被引:39
作者
PICOT, PA [1 ]
EMBREE, PM [1 ]
机构
[1] PHILIPS ULTRASOUND,SANTA ANA,CA 92705
关键词
D O I
10.1109/58.285468
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
The direct measurement of the velocity profile of blood flowing in a vessel yields a volume flow estimate that is more accurate than single-point Doppler ultrasound. A volume flow estimate is made by assuming a circularly symmetric velocity field and integrating the velocity profile measured along a diameter. The many velocity measurements made contribute to higher precision in the integrated velocity estimate. Also, the velocity profile furnishes the functional diameter of the vessel at many points through the cardiac cycle. This algorithm, as implemented on the Philips CVI(TM) system, was tested theoretically by numerical modelling, and experimentally with a flow simulator. The effect of beamwidth, vessel size, and measurement position misalignment on the volume flow estimate were studied. Experimental and theoretical results agreed well and showed that the flow estimation algorithm can produce precise and accurate volume flow estimates. The flow estimate is sensitive to the flow angle and is inaccurate by 5% per degree error in the angle. Beamwidths of 1.0 to 1.5 mm are a good match to axial resolution and yield accurate volume flow estimates in vessels over 2 mm in diameter. Larger beamwidths give lower volume flow estimates, but are not as sensitive to misalignment.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 9 条
[1]
TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[2]
TOPOFLOW - DIGITAL FULL RANGE DOPPLER VELOCITY METER [J].
BRANDESTINI, M .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (05) :287-293
[3]
VOLUMETRIC BLOOD-FLOW VIA TIME-DOMAIN CORRELATION - EXPERIMENTAL-VERIFICATION [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :176-189
[4]
FLOW VELOCITY PROFILE VIA TIME-DOMAIN CORRELATION ERROR ANALYSIS AND COMPUTER-SIMULATION [J].
FOSTER, SG ;
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :164-175
[6]
COMPUTER-CONTROLLED POSITIVE DISPLACEMENT PUMP FOR PHYSIOLOGICAL FLOW SIMULATION [J].
HOLDSWORTH, DW ;
RICKEY, DW ;
DRANGOVA, M ;
MILLER, DJM ;
FENSTER, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (06) :565-570
[7]
FLOW ESTIMATION USING ULTRASOUND IMAGING (COLOR M-MODE) AND COMPUTER POSTPROCESSING [J].
JUUL, R ;
SLORDAHL, SA ;
TORP, H ;
ANGELSEN, BAJ ;
BRUBAKK, AO .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (05) :879-882
[8]
MAGNIN PA, 1987, 1987 IEEE ULTR S P, V2, P967
[9]
A VELOCITY EVALUATION PHANTOM FOR COLOR AND PULSED DOPPLER INSTRUMENTS [J].
RICKEY, DW ;
RANKIN, R ;
FENSTER, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (05) :479-494