FIXATION OF MAMMALIAN-CELLS FOR FLOW CYTOMETRIC EVALUATION OF DNA CONTENT AND NUCLEAR IMMUNOFLUORESCENCE

被引:82
作者
SCHIMENTI, KJ [1 ]
JACOBBERGER, JW [1 ]
机构
[1] CASE WESTERN RESERVE UNIV, SCH MED, DEPT GENET, 4109 ADELBERT RD, CLEVELAND, OH 44106 USA
来源
CYTOMETRY | 1992年 / 13卷 / 01期
关键词
SV40; T-ANTIGEN; PARAFORMALDEHYDE; METHANOL; BIVARIATE ANALYSIS; CELL CYCLE; NIH; 3T3; RETROVIRAL VECTORS; CELL CYCLE GENE EXPRESSION;
D O I
10.1002/cyto.990130109
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mammalian tissue culture cells were fixed with 3 different alcoholic fixatives - acetone:methanol, EtOH, and MeOH. The quality of the resulting DNA histograms was evaluated by comparison of CV, G1/G2 ratio, G1 mode, cell aggregation, and debris formation; 81-90% MeOH (final concentration) was determined to be the optimal fixative by these criteria. A procedure was then examined using a prefix with paraformaldehyde followed by MeOH (PF/MeOH). This procedure produced cell preparations with reduced debris and aggregation, equivalent mode and ratio, but increased CV when compared with MeOH fixation. Both MeOH and PF/MeOH fixation procedures were then compared for their utility in dual staining for DNA and intracellular immunofluorescence for a nuclear protein, SV40 T antigen (Tag). Since alcohols are known to affect immunofluorescence staining of some antigens, fixation with paraformaldehyde followed by Triton X-100 permeabilization (PF/TX) was also included in this comparison to generalize the study by providing an alternative to MeOH permeabilization. The three procedures were evaluated for the quality of the sample by measuring the same descriptors of the DNA parameter as in the alcohol study. PF/TX consistently produced samples with decreased DNA CV and less debris and aggregation compared to MeOH methods. Two criteria were used to evaluate immunofluorescence - the amount of Tag measured and reproducibility. All MeOH methods were equivalently reproducible with CV's less than 3%. PF/TX was slightly less so with a CV of less than 6%. In contrast, different levels of Tag were measured for each procedure. For mouse 3T3 cells infected with a recombinant retroviral vector encoding T antigen, the level of T antigen measured after PF/MeOH was 21% greater than in MeOH fixed cells, and the level in PF/TX fixed cells was 37% less. The fraction of fluorescence specific to T antigen for these cells was 79-83% for all procedures. The lower levels measured after fixation by PF/TX were shown to be due to epitope masking. Why higher levels are measured with PF/MeOH procedures is unknown at present but may be due to antigen retention. Therefore, each of these fixation methods may be used with confidence in reliability but they are not equivalent with respect to the molecular architecture of the nucleus. It is postulated that PF/TX permeabilizes cells but cells retain native supramolecular structure, whereas MeOH based fixatives disrupt this structure and randomize availability of epitope to antibody. If so, the two procedures could be used as complementary procedures to study gene expression and function.
引用
收藏
页码:48 / 59
页数:12
相关论文
共 47 条
[31]   IMMUNOFLUORESCENT QUANTIFICATION OF RIBONUCLEOTIDE REDUCTASE M1 SUBUNIT AND CORRELATION WITH DNA CONTENT BY FLOW-CYTOMETRY [J].
MANN, GJ ;
DYNE, M ;
MUSGROVE, EA .
CYTOMETRY, 1987, 8 (05) :509-517
[32]   CONSTRUCTION OF A RETROVIRUS PACKAGING MUTANT AND ITS USE TO PRODUCE HELPER-FREE DEFECTIVE RETROVIRUS [J].
MANN, R ;
MULLIGAN, RC ;
BALTIMORE, D .
CELL, 1983, 33 (01) :153-159
[33]  
MOLE SE, 1989, IMMUNOLOGY, P80
[34]   DETERMINATION OF LINEAR FLUORESCENCE INTENSITIES FROM FLOW CYTOMETRIC DATA ACCUMULATED WITH LOGARITHMIC AMPLIFIERS [J].
MUIRHEAD, KA ;
SCHMITT, TC ;
MUIRHEAD, AR .
CYTOMETRY, 1983, 3 (04) :251-256
[35]   A METHOD FOR MEASURING LYMPHOCYTE-PROLIFERATION IN MIXED LYMPHOCYTE-CULTURES USING A NUCLEAR PROLIFERATION ANTIGEN, KI-67, AND FLOW-CYTOMETRY [J].
PALUTKE, M ;
TABACZKA, PM ;
KUKURUGA, DL ;
KANTOR, NL .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (04) :417-421
[36]   METABOLISM OF C-MYC GENE-PRODUCTS - C-MYC MESSENGER-RNA AND PROTEIN EXPRESSION IN THE CELL-CYCLE [J].
RABBITTS, PH ;
WATSON, JV ;
LAMOND, A ;
FORSTER, A ;
STINSON, MA ;
EVAN, G ;
FISCHER, W ;
ATHERTON, E ;
SHEPPARD, R ;
RABBITTS, TH .
EMBO JOURNAL, 1985, 4 (08) :2009-2015
[37]   A FLOW CYTOMETRIC TECHNIQUE FOR SIMULTANEOUS ANALYSIS OF HUMAN MONONUCLEAR CELL-SURFACE ANTIGENS AND DNA [J].
RIGG, KM ;
SHENTON, BK ;
MURRAY, IA ;
GIVAN, AL ;
TAYLOR, RMR ;
LENNARD, TWJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 123 (02) :177-184
[38]  
SHAPIRO HM, 1985, PRACTICAL FLOW CYTOM, P88
[39]  
SHEN DW, 1983, P NATL ACAD SCI-BIOL, V80, P5919, DOI 10.1073/pnas.80.19.5919
[40]   RAPID TITRATION OF RETROVIRAL VECTORS ENCODING INTRACELLULAR ANTIGENS BY FLOW-CYTOMETRY [J].
SLADEK, TL ;
JACOBBERGER, JW .
JOURNAL OF VIROLOGY, 1990, 64 (06) :3135-3138