VARIABILITY OF BREATHLESSNESS MEASUREMENT IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE

被引:69
作者
BELMAN, MJ
BROOKS, LR
ROSS, DJ
MOHSENIFAR, Z
机构
关键词
D O I
10.1378/chest.99.3.566
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The purpose of our study was to evaluate the reproducibility of a Borg rating of dyspnea in patients with COPD. We examined nine patients with COPD who performed a SST on four separate days within a ten-day period. The patients walked on a treadmill for 6 min. At the end of each minute, patients matched a Borg rating to the intensity of their breathlessness. We measured the HR, VE, VO2, VT and f at the end of each minute. While the mean VO2, VE, HR, VT and f stabilized after one or two attempts, the Borg ratings decreased with successive tests. We conclude that the Borg scale for measuring breathlessness shows progressive decreases with repetition whereas VO2, VE, HR, VT and f stabilize after one or two practice attempts. This suggests that desensitization to dyspnea may play a role in the improvement of patients after exercise.
引用
收藏
页码:566 / 571
页数:6
相关论文
共 32 条
[31]   A COMPARISON OF THE VISUAL ANALOG SCALE AND MODIFIED BORG SCALE FOR THE MEASUREMENT OF DYSPNEA DURING EXERCISE [J].
WILSON, RC ;
JONES, PW .
CLINICAL SCIENCE, 1989, 76 (03) :277-282
[32]  
WOLPE J, 1961, J NERV MENT DIS, V132, P1879