ON THE GENERALIZATION OF THE RECEIVER OPERATING CHARACTERISTIC ANALYSIS TO THE POPULATION OF READERS AND CASES WITH THE JACKKNIFE METHOD - AN ASSESSMENT

被引:13
作者
ROCKETTE, HE [1 ]
GUR, D [1 ]
KURSLASKY, M [1 ]
KING, JL [1 ]
机构
[1] UNIV PITTSBURGH,DEPT BIOSTAT,PITTSBURGH,PA 15261
关键词
RECEIVER OPERATING CHARACTERISTIC CURVE; JACKKNIFE CASE-READER VARIABILITY;
D O I
10.1016/S1076-6332(05)80249-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. A new methodology that analyzes receiver operating characteristic (ROC) data sets based on jackknifing and that considers both case and reader variability has been proposed. The purpose of this investigation was to compare results using this method to those using commonly reported methodology. Methods. ROC data sets using discrete and continuous rating scales were analyzed using the proposed jackknifing method, and results were compared to analysis of the same data sets using the paired t test. Results. The two methodologies did not result in the same significance levels, and in some cases, the difference was sufficient to affect conclusions regarding comparisons of diagnostic modalities. The probability value for the jackknifing procedure is based on large sample distribution theory, and its appropriateness is unknown for sample sizes used in practice. Also, the jackknifing technique was found to be sensitive to outliers resulting when data from the computer programs used to estimate area under the ROC curve failed to converge. Conclusion. Although the proposed methodology yields reasonable results, several fundamental and practical issues must be addressed before it can be used widely as the analytic method of choice in ROC studies comparing different imaging techniques or reading environments.
引用
收藏
页码:66 / 69
页数:4
相关论文
共 19 条
[1]   A MODEL FOR AGREEMENT BETWEEN RATINGS ON AN ORDINAL SCALE [J].
AGRESTI, A .
BIOMETRICS, 1988, 44 (02) :539-548
[2]   JACKKNIFING U-STATISTICS [J].
ARVESEN, JN .
ANNALS OF MATHEMATICAL STATISTICS, 1969, 40 (06) :2076-&
[3]   ROBUST PROCEDURES FOR VARIANCE COMPONENT PROBLEMS USING JACKKNIFE [J].
ARVESEN, JN ;
SCHMITZ, TH .
BIOMETRICS, 1970, 26 (04) :677-&
[4]   MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1989, 16 (04) :561-568
[5]   CHEST RADIOGRAPHY - COMPARISON OF HIGH-RESOLUTION DIGITAL DISPLAYS WITH CONVENTIONAL AND DIGITAL FILM [J].
COX, GG ;
COOK, LT ;
MCMILLAN, JH ;
ROSENTHAL, SJ ;
DWYER, SJ .
RADIOLOGY, 1990, 176 (03) :771-776
[6]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[7]  
EFRON B, 1993, INTRO BOOTSTRAP, P145
[8]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[9]   SPATIAL-RESOLUTION REQUIREMENTS FOR DIGITAL CHEST RADIOGRAPHS - AN ROC STUDY OF OBSERVER PERFORMANCE IN SELECTED CASES [J].
LAMS, PM ;
COCKLIN, ML .
RADIOLOGY, 1986, 158 (01) :11-19
[10]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26