INITIATION OF COHERENT MAGNETRON MOTION FOLLOWING ION INJECTION INTO A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE TRAPPED ION CELL

被引:17
作者
HENDRICKSON, CL [1 ]
HOFSTADLER, SA [1 ]
BEU, SC [1 ]
LAUDE, DA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM & BIOCHEM,AUSTIN,TX 78712
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1993年 / 123卷 / 01期
关键词
FT-ICR; LASER DESORPTION IONIZATION; ELECTROSPRAY IONIZATION; MAGNETRON MOTION;
D O I
10.1016/0168-1176(93)87053-U
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The initiation and growth of coherent magnetron motion for ions injected into a Fourier transform ion cyclotron resonance trapped ion cell is investigated. The phenomenon is demonstrated for laser desorption/ionization (LDI) of metals and salts and for electrospray ionization (ESI) of multiply charged proteins. In all cases, the rate of growth of the magnetron orbit increases proportionally with trap potential, ion density, and external detection circuit resistance. The data support resistive damping of the magnetron motion as the primary relaxation mechanism leading to ion ejection from the cell within time periods ranging from a few hundred milliseconds to tens of seconds. Factors associated with ion injection that contribute to initiation and growth of the destabilizing motion are length of the injection period relative to the magnetron period and extent of off-axis injection. In general, if the injection period is smaller than one period of the magnetron motion, as is the case for LDI, and the injection point is severely off the centerline of the cell, coherent growth is observed instantaneously and ions are expelled from the cell within a few hundred milliseconds. If the LDI ions are introduced along the centerline, coherent motion leading to expulsion is still observed but initiation times increase ten-fold. For the case in which ESI ions focused along the centerline are injected into the trap for a time much longer than the period of a magnetron oscillation, initiation and growth of coherent magnetron is only observed at much longer times and with a larger trap potential.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 32 条
[11]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES [J].
HENRY, KD ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) :5447-5449
[12]  
HOFSTADLER SA, 1992, ANAL CHEM, V64, P572
[13]  
HOGAN JD, 1991, ANAL CHEM, V63, P1457
[14]   A MECHANISM FOR POOR HIGH MASS PERFORMANCE IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
HOLLIMAN, CL ;
REMPEL, DL ;
GROSS, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :460-463
[15]   COOLING OF PARTICLES STORED IN ELECTROMAGNETIC TRAPS [J].
HOLZSCHEITER, MH .
PHYSICA SCRIPTA, 1988, T22 :73-78
[16]   MASS-DEPENDENT Z-EXCITATION OF IONS IN CUBIC TRAPS USED IN FTMS [J].
HUANG, SK ;
REMPEL, DL ;
GROSS, ML .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2) :15-31
[17]   TANDEM QUADRUPOLE FOURIER-TRANSFORM MASS-SPECTROMETRY OF OLIGOPEPTIDES [J].
HUNT, DF ;
SHABANOWITZ, J ;
YATES, JR ;
MCIVER, RT ;
HUNTER, RL ;
SYKA, JEP ;
AMY, J .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2728-2733
[18]   TANDEM QUADRUPOLE FOURIER-TRANSFORM MASS-SPECTROMETRY OF OLIGOPEPTIDES AND SMALL PROTEINS [J].
HUNT, DF ;
SHABANOWITZ, J ;
YATES, JR ;
ZHU, NZ ;
RUSSELL, DH ;
CASTRO, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1987, 84 (03) :620-623
[19]   IONIZATION AND MASS ANALYSIS OF NONVOLATILE COMPOUNDS BY PARTICLE BOMBARDMENT TANDEM-QUADRUPOLE FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
HUNT, DF ;
SHABANOWITZ, J ;
MCIVER, RT ;
HUNTER, RL ;
SYKA, JEP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :765-768
[20]   AN EXTERNAL SECONDARY ION-SOURCE FOR FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
IJAMES, CF ;
WILKINS, CL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (03) :208-216