LOCALIZATION OF IMPLANTED DIPOLES BY MAGNETOENCEPHALOGRAPHY

被引:38
作者
BALISH, M
SATO, S
CONNAUGHTON, P
KUFTA, C
机构
关键词
MAGNETIC LOCALIZATION; MODEL; FIELD; EEG; SIMULATION; EPILEPSY; SPHERE; HEAD;
D O I
10.1212/WNL.41.7.1072
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We attempted to validate the location of sources predicted by magnetoencephalography (MEG) by studying 19 specially designed dipole electrodes implanted in six patients with intractable partial seizures who were undergoing subdural electrode recording. We used a seven-channel magnetometer to measure the magnetic fields produced by passing through the dipoles a 40-mu-A, 5-msec square-wave pulse followed 40 msec later by a pulse of opposite polarity; 200 pulses were averaged for each magnetometer position. The actual dipole locations were measured from skull radiographs, and we based MEG localization on a spherical head model with the inclusion of volume currents. MEG estimates of the sources were within several centimeters (mean, 1.69 cm) of the measured locations. We conclude that MEG localization was promising.
引用
收藏
页码:1072 / 1076
页数:5
相关论文
共 20 条
  • [1] MAGNETIC LOCALIZATION OF A DIPOLAR CURRENT SOURCE IMPLANTED IN A SPHERE AND A HUMAN CRANIUM
    BARTH, DS
    SUTHERLING, W
    BROFFMAN, J
    BEATTY, J
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 63 (03): : 260 - 273
  • [2] BUCHANAN DS, 1990, ADV BIOMAGNETISM, P539
  • [3] MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    COHEN, D
    CUFFIN, BN
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, JG
    SCHOMER, DL
    [J]. ANNALS OF NEUROLOGY, 1990, 28 (06) : 811 - 817
  • [4] FEASIBILITY OF THE HOMOGENEOUS HEAD MODEL IN THE INTERPRETATION OF NEUROMAGNETIC FIELDS
    HAMALAINEN, MS
    SARVAS, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (01) : 91 - 97
  • [5] SPATIAL-RESOLUTION OF NEUROMAGNETIC RECORDS - THEORETICAL CALCULATIONS IN A SPHERICAL MODEL
    HARI, R
    JOUTSINIEMI, SL
    SARVAS, J
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 71 (01): : 64 - 72
  • [6] HARI R, 1986, CRIT REV BIOMED ENG, V14, P93
  • [7] LOCALIZATION OF EQUIVALENT DIPOLES OF EEG SOURCES BY APPLICATION OF ELECTRICAL-FIELD THEORY
    HENDERSON, CJ
    BUTLER, SR
    GLASS, A
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 39 (02): : 117 - 130
  • [8] ANALYSIS OF MAGNETOENCEPHALOGRAPHIC DATA USING THE HOMOGENEOUS SPHERE MODEL - EMPIRICAL TESTS
    JANDAY, BS
    SWITHENBY, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (01) : 105 - 113
  • [9] LOCATING ACCURACY OF A CURRENT SOURCE OF NEUROMAGNETIC RESPONSES - SIMULATION STUDY FOR A SINGLE CURRENT DIPOLE IN A SPHERICAL CONDUCTOR
    KURIKI, S
    MURASE, M
    TAKEUCHI, F
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1989, 73 (06): : 499 - 506
  • [10] ON THE MAGNETIC-FIELD DISTRIBUTION GENERATED BY A DIPOLAR CURRENT SOURCE SITUATED IN A REALISTICALLY SHAPED COMPARTMENT MODEL OF THE HEAD
    MEIJS, JWH
    BOSCH, FGC
    PETERS, MJ
    DASILVA, FHL
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1987, 66 (03): : 286 - 298