Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model

被引:12
作者
Shiota, T
Jones, M
Aida, S
Chikada, M
Tsujino, H
El-Kadi, T
Sahn, DJ
机构
[1] NHLBI, Lab Anim Med & Surg, Bethesda, MD 20892 USA
[2] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[3] Toshiba Corp, Tokyo, Japan
[4] Oregon Hlth Sci Univ, Portland, OR 97201 USA
关键词
D O I
10.1016/S0735-1097(99)00210-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of the present study was to quantitate shunt flow volumes through atrial septal defects (ASDs) in a chronic animal model with surgically created ASDs using a new semiautomated color Doppler flow calculation method (ACM). BACKGROUND Because pulsed Doppler is cumbersome and often inappropriate for color flow computation, new methods such as ACM are of interest. METHODS In this study, 13 to 25 weeks after ASDs were surgically created in eight sheep, a total of 24 hemodynamic states were studied at a separate open chest experimental session. Electromagnetic (EM) flow probes and meters were used to provide reference flow volumes as the pulmonary and aortic flow volumes (Q(p) and Q(s)) and shunt flow volumes (Q(p) minus Q(s)). Epicardial echocardiographic studies were performed to image the left and right ventricular outflow tract (LVOT and RVOT) forward flow signals. The ACM method digitally integrated spatial and temporal color flow velocity data to provide stroke volumes. RESULTS Left ventricular outflow tract and RVOT flow volumes obtained by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = 0.78 +/- 1.7 mi for LVOT and r = 0.97, mean difference = -0.35 +/- 3.6 mi for RVOT). As a result, shunt flow volumes and Q(p)/Q(s) by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = -1.1 +/- 3.6 ml/beat for shunt volumes and r = 0.95, mean difference = -0.11 +/- 0.22 for Q(p)/Q(s)). CONCLUSIONS This animal study, using strictly quantified shunt flow volumes, demonstrated that the ACM method can provide Q(p)/Q(s), and shunt measurements semiautomatically and noninvasively. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 30 条
[1]   Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: An in vitro study [J].
Aida, S ;
Shiota, T ;
Tsujino, H ;
Sahn, DJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (09) :874-881
[2]   CLINICAL UTILITY OF TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHIC TECHNIQUES FOR ESTIMATING PULMONARY TO SYSTEMIC BLOOD-FLOW RATIOS IN CHILDREN WITH LEFT TO RIGHT SHUNTING ATRIAL SEPTAL-DEFECT, VENTRICULAR SEPTAL-DEFECT OR PATENT DUCTUS-ARTERIOSUS [J].
BARRON, JV ;
SAHN, DJ ;
VALDESCRUZ, LM ;
LIMA, CO ;
GOLDBERG, SJ ;
GRENADIER, E ;
ALLEN, HD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :169-178
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS [J].
FISHER, DC ;
SAHN, DJ ;
FRIEDMAN, MJ ;
LARSON, D ;
VALDESCRUZ, LM ;
HOROWITZ, S ;
GOLDBERG, SJ ;
ALLEN, HD .
CIRCULATION, 1983, 67 (02) :370-376
[5]  
Glantz SA, 1990, PRIMER APPL REGRESSI, P381
[6]   EVALUATION OF PULMONARY AND SYSTEMIC BLOOD-FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY USING FAST FOURIER-TRANSFORM SPECTRAL-ANALYSIS [J].
GOLDBERG, SJ ;
SAHN, DJ ;
ALLEN, HD ;
VALDESCRUZ, LM ;
HOENECKE, H ;
CARNAHAN, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) :1394-1400
[7]   BIPLANE TRANSESOPHAGEAL ECHO-DOPPLER STUDIES OF ATRIAL SEPTAL-DEFECTS - QUANTITATIVE-EVALUATION AND MONITORING FOR TRANSCATHETER CLOSURE [J].
ISHII, M ;
KATO, H ;
INOUE, O ;
TAKAGI, J ;
MAENO, Y ;
SUGIMURA, T ;
MIYAKE, T ;
KUMATE, M ;
KOSUGA, K ;
OHISHI, K .
AMERICAN HEART JOURNAL, 1993, 125 (05) :1363-1368
[8]  
JONES M, 1982, CARDIAC BIOPROSTHESE, P275
[9]   A new Doppler method for quantification of volumetric flow: In vivo validation using color Doppler [J].
Kim, WY ;
Poulsen, JK ;
Terp, K ;
Staalsen, NH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (01) :182-192
[10]   NON-INVASIVE EVALUATION OF THE RATIO OF PULMONARY TO SYSTEMIC FLOW IN ATRIAL SEPTAL-DEFECT BY DUPLEX DOPPLER ECHOCARDIOGRAPHY [J].
KITABATAKE, A ;
INOUE, M ;
ASAO, M ;
ITO, H ;
MASUYAMA, T ;
TANOUCHI, J ;
MORITA, T ;
HORI, M ;
YOSHIMA, H ;
OHNISHI, K ;
ABE, H .
CIRCULATION, 1984, 69 (01) :73-79