Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model

被引:12
作者
Shiota, T
Jones, M
Aida, S
Chikada, M
Tsujino, H
El-Kadi, T
Sahn, DJ
机构
[1] NHLBI, Lab Anim Med & Surg, Bethesda, MD 20892 USA
[2] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[3] Toshiba Corp, Tokyo, Japan
[4] Oregon Hlth Sci Univ, Portland, OR 97201 USA
关键词
D O I
10.1016/S0735-1097(99)00210-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of the present study was to quantitate shunt flow volumes through atrial septal defects (ASDs) in a chronic animal model with surgically created ASDs using a new semiautomated color Doppler flow calculation method (ACM). BACKGROUND Because pulsed Doppler is cumbersome and often inappropriate for color flow computation, new methods such as ACM are of interest. METHODS In this study, 13 to 25 weeks after ASDs were surgically created in eight sheep, a total of 24 hemodynamic states were studied at a separate open chest experimental session. Electromagnetic (EM) flow probes and meters were used to provide reference flow volumes as the pulmonary and aortic flow volumes (Q(p) and Q(s)) and shunt flow volumes (Q(p) minus Q(s)). Epicardial echocardiographic studies were performed to image the left and right ventricular outflow tract (LVOT and RVOT) forward flow signals. The ACM method digitally integrated spatial and temporal color flow velocity data to provide stroke volumes. RESULTS Left ventricular outflow tract and RVOT flow volumes obtained by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = 0.78 +/- 1.7 mi for LVOT and r = 0.97, mean difference = -0.35 +/- 3.6 mi for RVOT). As a result, shunt flow volumes and Q(p)/Q(s) by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = -1.1 +/- 3.6 ml/beat for shunt volumes and r = 0.95, mean difference = -0.11 +/- 0.22 for Q(p)/Q(s)). CONCLUSIONS This animal study, using strictly quantified shunt flow volumes, demonstrated that the ACM method can provide Q(p)/Q(s), and shunt measurements semiautomatically and noninvasively. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 30 条
[11]   THE EFFECTS OF SAMPLING SITE ON THE 2-DIMENSIONAL ECHO-DOPPLER DETERMINATION OF CARDIAC-OUTPUT [J].
LABOVITZ, AJ ;
BUCKINGHAM, TA ;
HABERMEHL, K ;
NELSON, J ;
KENNEDY, HL ;
WILLIAMS, GA .
AMERICAN HEART JOURNAL, 1985, 109 (02) :327-332
[12]   TRANSESOPHAGEAL DOPPLER COLOR FLOW MAPPING ASSESSMENT OF ATRIAL SEPTAL-DEFECT [J].
MEHTA, RH ;
HELMCKE, F ;
NANDA, NC ;
HSIUNG, M ;
PACIFICO, AD ;
HSU, TL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :1010-1016
[13]   NONINVASIVE PULSED DOPPLER ECHOCARDIOGRAPHIC DETECTION OF THE DIRECTION OF SHUNT FLOW IN PATIENTS WITH ATRIAL SEPTAL-DEFECT - USEFULNESS OF THE RIGHT PARASTERNAL APPROACH [J].
MINAGOE, S ;
TEI, C ;
KISANUKI, A ;
ARIKAWA, K ;
NAKAZONO, Y ;
YOSHIMURA, H ;
KASHIMA, T ;
TANAKA, H .
CIRCULATION, 1985, 71 (04) :745-753
[14]   ESTIMATION OF RIGHT AND LEFT VENTRICULAR SIZE BY ULTRASOUND - A STUDY OF ECHOES FROM INTERVENTRICULAR SEPTUM [J].
POPP, RL ;
WOLFE, SB ;
HIRATA, T ;
FEIGENBAUM, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1969, 24 (04) :523-+
[15]   AN ECHOCARDIOGRAPHIC INDEX FOR SEPARATION OF RIGHT VENTRICULAR VOLUME AND PRESSURE OVERLOAD [J].
RYAN, T ;
PETROVIC, O ;
DILLON, JC ;
FEIGENBAUM, H ;
CONLEY, MJ ;
ARMSTRONG, WF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (04) :918-924
[16]   Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: An animal study with quantified chronic aortic regurgitation [J].
Shiota, T ;
Jones, M ;
Aida, S ;
Tsujino, H ;
Yamada, I ;
Delabays, A ;
Pandian, NG ;
Sahn, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :834-842
[17]   Effective regurgitant orifice area by the color Doppler flaw convergence method for evaluating the severity of chronic aortic regurgitation - An animal study [J].
Shiota, T ;
Jones, M ;
Yamada, I ;
Heinrich, RS ;
Ishii, M ;
Sinclair, B ;
Holcomb, S ;
Yoganathan, AP ;
Sahn, DJ .
CIRCULATION, 1996, 93 (03) :594-602
[18]   Evaluation of aortic regurgitation with digitally determined color Doppler-imaged flow convergence acceleration: A quantitative study in sheep [J].
Shiota, T ;
Jones, M ;
Yamada, I ;
Heinrich, RS ;
Ishii, M ;
Sinclair, B ;
Yoganathan, AP ;
Sahn, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (01) :203-210
[19]   SURGICAL REPAIR OF UNCOMPLICATED ATRIAL SEPTAL-DEFECT WITHOUT ROUTINE PREOPERATIVE CARDIAC-CATHETERIZATION [J].
SHUB, C ;
TAJIK, AJ ;
SEWARD, JB ;
HAGLER, DJ ;
DANIELSON, GK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (01) :49-54
[20]  
SJORBERG BJ, 1994, J AM SOC ECHOCARDIOG, V7, P276