RELIABILITY OF AUTOMATED PLATELET COUNTS - COMPARISON WITH MANUAL METHOD AND UTILITY FOR PREDICTION OF CLINICAL BLEEDING

被引:25
作者
LAWRENCE, JB
YOMTOVIAN, RA
DILLMAN, C
MASARIK, SR
CHONGKOLWATANA, V
CREGER, RJ
MANKA, A
HAMMONS, T
LAZARUS, HM
机构
[1] UNIV HOSP CLEVELAND, CLEVELAND, OH USA
[2] CASE WESTERN RESERVE UNIV, SCH MED, CLEVELAND, OH USA
关键词
PLATELET COUNTS; HEMOSTASIS; HEMORRHAGE; AUTOMATED HEMATOLOGY ANALYZERS; THROMBOCYTOPENIA;
D O I
10.1002/ajh.2830480408
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The 20 x 10(9)/L (20,000/mu l) threshold for prophylactic platelet transfusion may be unnecessarily high. The widespread use of this threshold may reflect lack of confidence in the reliability of low platelet counts. We evaluated the performance of automated platelet counts and their relation to clinical bleeding. First, we prepared serial blood dilutions with ''target'' platelet counts from 2 to 40 x 10(9)/L. For the 48 measurements on 2 x 10(9)/L ''target'' dilutions, values of 1 or 2 x 10(9)/L were obtained with the Sysmex NE-8000 analyzer (mean 1.44 x 10(9)/L; SD 0.31 x 10(9)/L). Similarly, for 5 x 10(9)/L ''target'' counts, automated counts were 3-6 x 10(9)/L(mean 4.42 x 10(9)/L; SD 0.18 x 10(9)/L). Similar results were observed with all other ''target'' levels, with coefficients of variation (CV) from 6.39% to 7.71% with 10-40 x 10(9)/L ''target'' values. Secondly, we compared triplicate automated and manual platelet counts on thrombocytopenic patients with platelet counts from 4-30 x 10(9)/L. The triplicate automated platelet counts differed by no more than 5 x 10(9)/L among themselves, whereas the manual counts varied by as much as 30 x 10(9)/L. Mean platelet counts: automated, 14.40 x 10(9)/L(CV 10.12%); manual, 16.48 x 10(9)/L(CV 30.39%) (P = 0.038 for counts; P < 0.001 for CV). Finally, we prospectively evaluated bleeding in thrombocytopenic patients (1,809 patient-days of observation). Univariate and multivariate logistic regression analysis revealed highly significant correlations between the automated platelet count and major and minor bleeding manifestations. Thus, automated platelet counts are highly reliable and accurately predict clinical bleeding. The use of automated analyzers should facilitate improved prophylactic platelet transfusion protocols. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:244 / 250
页数:7
相关论文
共 29 条
[21]   PLATELET UTILIZATION IN A UNIVERSITY HOSPITAL [J].
MCCULLOUGH, J ;
STEEPER, TA ;
CONNELLY, DP ;
JACKSON, B ;
HUNTINGTON, S ;
SCOTT, EP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (16) :2414-2418
[22]  
MORROW J F, 1991, Journal of the American Medical Association, V266, P555, DOI 10.1001/jama.266.4.555
[23]  
NOSANCHUK JS, 1978, AM J CLIN PATHOL, V69, P383
[24]  
ONDER O, 1980, BLOOD, V56, P177
[25]   CONTROVERSIES IN TRANSFUSION MEDICINE - PROPHYLACTIC PLATELET TRANSFUSION REVISITED AFTER 25 YEARS - CON [J].
PATTEN, E .
TRANSFUSION, 1992, 32 (04) :381-385
[26]   PSEUDOTHROMBOCYTOPENIA - MANIFESTATION OF A NEW TYPE OF PLATELET AGGLUTININ [J].
SHREINER, DP ;
BELL, WR .
BLOOD, 1973, 42 (04) :541-549
[27]  
VANWERSCH JWJ, 1990, J CLIN CHEM CLIN BIO, V28, P233
[28]   A PROSPECTIVE MICROBIOLOGIC SURVEILLANCE PROGRAM TO DETECT AND PREVENT THE TRANSFUSION OF BACTERIALLY CONTAMINATED PLATELETS [J].
YOMTOVIAN, R ;
LAZARUS, HM ;
GOODNOUGH, LT ;
HIRSCHLER, NV ;
MORRISSEY, AM ;
JACOBS, MR .
TRANSFUSION, 1993, 33 (11) :902-909
[29]  
1987, JAMA-J AM MED ASSOC, V257, P1777