NEW METHODS FOR CALCULATING KINETIC-PROPERTIES OF CELLS-INVITRO USING PULSE LABELING WITH BROMODEOXYURIDINE

被引:44
作者
WHITE, RA [1 ]
TERRY, NHA [1 ]
MEISTRICH, ML [1 ]
机构
[1] UNIV TEXAS,MD ANDERSON CANCER CTR,DEPT EXPTL RADIOTHERAPY,HOUSTON,TX 77030
来源
CELL AND TISSUE KINETICS | 1990年 / 23卷 / 06期
关键词
D O I
10.1111/j.1365-2184.1990.tb01346.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The transit times of Chinese hamster ovary cells through the phase of their cell cycle were measured using dual parameter flow cytometry to measure DNA content and the presence of monoclonal antibodies to bromodeoxyuridine. Up to four separate populations can be accurately measured: unlabelled cells in G2 + M; labelled cells that have not yet divided; labelled cells that have already divided; and the unlabelled cells that were originally in G1 plus the cells that were originally in G2 + M and have since divided. The fractions of cells in these populations can be easily followed in time and the usual kinetic properties can be estimated from these fractions, or combinations thereof, including the times through G1, S, G2 + M and the cycle time. We present equations for analysing this type of data and comment on which equations are most appropriate for measuring specific kinetic properties of the cells.
引用
收藏
页码:561 / 573
页数:13
相关论文
共 19 条
  • [1] A METHOD TO MEASURE THE DURATION OF DNA-SYNTHESIS AND THE POTENTIAL DOUBLING TIME FROM A SINGLE SAMPLE
    BEGG, AC
    MCNALLY, NJ
    SHRIEVE, DC
    KARCHER, H
    [J]. CYTOMETRY, 1985, 6 (06): : 620 - 626
  • [2] FLOW CYTOMETRIC MEASUREMENT OF TOTAL DNA CONTENT AND INCORPORATED BROMODEOXYURIDINE
    DOLBEARE, F
    GRATZNER, H
    PALLAVICINI, MG
    GRAY, JW
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1983, 80 (18): : 5573 - 5577
  • [4] JAGERS P, 1975, BRANCHING PROCESSES
  • [5] AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS
    MARQUARDT, DW
    [J]. JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02): : 431 - 441
  • [6] RICCARDI A, 1988, CANCER RES, V48, P6238
  • [7] FLOW CYTOMETRIC ESTIMATION OF CELL-CYCLE PARAMETERS USING A MONOCLONAL-ANTIBODY TO BROMODEOXYURIDINE
    SASAKI, K
    MURAKAMI, T
    OGINO, T
    TAKAHASHI, M
    KAWASAKI, S
    [J]. CYTOMETRY, 1986, 7 (04): : 391 - 395
  • [8] A RAPID AND SIMPLE ESTIMATION OF CELL-CYCLE PARAMETERS BY CONTINUOUS LABELING WITH BROMODEOXYURIDINE
    SASAKI, K
    MURAKAMI, T
    TAKAHASHI, M
    [J]. CYTOMETRY, 1987, 8 (05): : 526 - 528
  • [9] AN IMPROVED METHOD FOR THE IMMUNOCYTOCHEMICAL DETECTION OF BROMODEOXYURIDINE LABELED NUCLEI USING FLOW-CYTOMETRY
    SCHUTTE, B
    REYNDERS, MMJ
    VANASSCHE, CLMVJ
    HUPPERETS, PSGJ
    BOSMAN, FT
    BLIJHAM, GH
    [J]. CYTOMETRY, 1987, 8 (04): : 372 - 376
  • [10] IMPROVED METHOD FOR COMPUTING POTENTIAL DOUBLING TIME FROM FLOW CYTOMETRIC DATA
    WHITE, RA
    TERRY, NHA
    MEISTRICH, ML
    CALKINS, DP
    [J]. CYTOMETRY, 1990, 11 (02): : 314 - 317