COMPARISON OF MASS-SPECTROMETRIC TECHNIQUES FOR THE ANALYSIS OF TRACE AMOUNTS OF 1-METHYLAMINOANTHRAQUINONE, USED AS SMOKE DYE IN EXPLODING MONEY SUITCASES

被引:6
作者
VERWEIJ, AMA
LIPMAN, PJL
机构
[1] Department of General Chemistry, Forensic Science Laboratory, the Ministry of Justice, 2288 GD Rijswijk
关键词
D O I
10.1016/0021-9673(93)83196-Y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Results are presented for different chromatographic and mass spectrometric methods of analysis of the smoke dye MAAQ. When applying gas chromatography various mass spectrometric (ionization) methods can be employed to reach the low picogram range, but for difficult samples full of other dirt preference has to be given to an MS-MS method in the daughter (negative) ion mode. The results of LC-thermospray-MS and LC-thermospray-MS-MS are somewhat less sensitive.
引用
收藏
页码:359 / 362
页数:4
相关论文
共 4 条
[1]  
MARTZ RM, 1983, J FORENSIC SCI, V28, P200
[2]  
NIESSENWAM, 1992, LIQUID CHROMATOGRAPH, P51
[3]   QUANTITATIVE LIQUID-CHROMATOGRAPHY, THERMOSPRAY TANDEM MASS-SPECTROMETRY (LC TSP MS MS) ANALYSIS OF SOME THERMOLABILE BENZODIAZEPINES IN WHOLE-BLOOD [J].
VERWEIJ, AMA ;
LIPMAN, PJL ;
ZWEIPFENNING, PGM .
FORENSIC SCIENCE INTERNATIONAL, 1992, 54 (01) :67-74
[4]  
Yinon J, 1991, FORENSIC SCI PROG, V5, P1