INITIAL FEASIBILITY STUDIES USING SINGLE-SHOT EPI FOR THE DETECTION OF FOCAL LIVER-LESIONS

被引:22
作者
REIMER, P
LADEBECK, R
RUMMENY, EJ
REPP, H
SCHMITT, F
BONGARTZ, G
SCHUIERER, G
LANGE, T
PETERS, PE
机构
[1] SIEMENS AG,DIV MR RES & DEV,W-8520 ERLANGEN,GERMANY
[2] DEPT ABDOMINAL & TRANSPLANTAT SURG,HANNOVER,GERMANY
关键词
EPI; SINGLE-SHOT; FOCAL LIVER LESIONS; DETECTION;
D O I
10.1002/mrm.1910320608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo planar MR imaging (EPI) has been developed to completely eliminate motion artifacts and is currently being prepared for implementation into clinical MR systems. Thus, the purpose of this study was to evaluate the clinical utility of EPI in the detection of focal liver lesions and to compare EPI with contrast-enhanced CT. EPI studies were performed on an experimental 1.0 Tesla whole body system using fat-suppressed single-shot spin echo (SE) and inversion recovery (IR) pulse sequences. A total of 26 liver tumors in 12 patients scheduled for liver resection were prospectively examined and correlated with intraoperative ultrasound, surgery, and pathology as the gold standard. Quantitative analysis of EPI was performed by means of liver signal-to-noise and tumor-liver contrast-to-noise calculations. Diagnostic performance e compared with contrast-enhanced CT was assessed by means of ROC analysis. Lesion-liver contrast was highest with EPI SE at a TE-time of 70 ms and this technique showed best lesion detectability as measured by area under curve (AUC) values. Among EPI techniques, the IR sequence with an inversion time of 300 ms to null the liver signal showed high lesion-liver contrast but all four reviewers reported problems assessing liver anatomy. Improved EPI techniques may prove useful for screening of focal liver lesions.
引用
收藏
页码:733 / 737
页数:5
相关论文
共 34 条
  • [11] DIFFERENTIATION BETWEEN HEMANGIOMAS AND METASTASES OF THE LIVER WITH ULTRAFAST MR IMAGING - PRELIMINARY-RESULTS WITH T2 CALCULATIONS
    GOLDBERG, MA
    SAINI, S
    HAHN, PF
    EGGLIN, TK
    MUELLER, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) : 727 - 730
  • [12] AN AQUEOUS GASTROINTESTINAL CONTRAST AGENT FOR USE IN ECHO-PLANAR MR IMAGING
    HAHN, PF
    SAINI, S
    COHEN, MS
    GOLDBERG, M
    REIMER, P
    MUELLER, PR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 380 - 383
  • [13] SPIRAL(HELICAL) CT
    HEIKEN, JP
    BRINK, JA
    VANNIER, MW
    [J]. RADIOLOGY, 1993, 189 (03) : 647 - 656
  • [14] DETECTION OF FOCAL HEPATIC MASSES - PROSPECTIVE EVALUATION WITH CT, DELAYED CT, CT DURING ARTERIAL PORTOGRAPHY, AND MR IMAGING
    HEIKEN, JP
    WEYMAN, PJ
    LEE, JKT
    BALFE, DM
    PICUS, D
    BRUNT, EM
    FLYE, MW
    [J]. RADIOLOGY, 1989, 171 (01) : 47 - 51
  • [15] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833
  • [16] MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03): : L55 - L58
  • [17] BASIC PRINCIPLES OF ROC ANALYSIS
    METZ, CE
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) : 283 - 298
  • [19] HEPATIC-TUMORS - COMPARISON OF CT DURING ARTERIAL PORTOGRAPHY, DELAYED CT, AND MR IMAGING FOR PREOPERATIVE EVALUATION
    NELSON, RC
    CHEZMAR, JL
    SUGARBAKER, PH
    BERNARDINO, ME
    [J]. RADIOLOGY, 1989, 172 (01) : 27 - 34
  • [20] GRASE (GRADIENT-ECHO AND SPIN-ECHO) IMAGING - A NOVEL FAST MRI TECHNIQUE
    OSHIO, K
    FEINBERG, DA