REAL-TIME NMR BEAM-DIRECTED VELOCITY MAPPING - V-MODE NMR

被引:10
作者
PEARLMAN, JD
MOORE, JR
LIZAK, MJ
机构
[1] HARVARD UNIV, MASSACHUSETTS GEN HOSP, SCH MED, DEPT MED, BOSTON, MA 02114 USA
[2] HARVARD UNIV, MASSACHUSETTS GEN HOSP, SCH MED, DEPT RADIOL, BOSTON, MA 02114 USA
关键词
BLOOD FLOW; MAGNETIC RESONANCE IMAGING; REAL TIME; PULSE SEQUENCE;
D O I
10.1161/01.CIR.86.5.1433
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Currently available noninvasive techniques for measuring blood flow velocities are constrained by limited view orientations (Doppler ultrasound) or limited time resolution (magnetic resonance imaging, MRI). We describe an MRI technique for measuring flow velocities in real time at arbitrary orientations within a cylindrical volume or "beam": V-mode nuclear magnetic resonance (NMR). Methods and Results. The technique was implemented on a standard 1.5-T clinical NMR imager with no special hardware and was tested on phantoms and human volunteers. The beam can be fired at rates up to 60 times per second, allowing measurements on a time scale that is appropriate for ungated cardiac studies. In phantoms, steady flow velocities were measured with the beam aligned along the direction of flow, and the measured velocities correlated well with the actual velocities (r>0.99). The radial distribution of velocities in phantoms under constant flow conditions was also determined. In humans, flow of blood in the descending aortas of normal and aortic insufficiency subjects was measured. Distinctive backflow of blood because of aortic insufficiency was readily apparent. Conclusions. The V-mode NMR technique is capable of acquiring clinically relevant real-time blood flow information from any desired angle of view with no attenuation at bone or air-tissue interfaces.
引用
收藏
页码:1433 / 1438
页数:6
相关论文
共 17 条
  • [1] FLOW PHENOMENA IN MR IMAGING
    BRADLEY, WG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) : 983 - 994
  • [2] MR MEASUREMENT OF BLOOD-FLOW IN THE TRUE AND FALSE CHANNEL IN CHRONIC AORTIC DISSECTION
    CHANG, JM
    FRIESE, K
    CAPUTO, GR
    KONDO, C
    HIGGINS, CB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (03) : 418 - 423
  • [3] MAGNETIC-RESONANCE ANGIOGRAPHY
    DUMOULIN, CL
    HART, HR
    [J]. RADIOLOGY, 1986, 161 (03) : 717 - 720
  • [4] THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT
    FIRMIN, DN
    NAYLER, GL
    KILNER, PJ
    LONGMORE, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 230 - 241
  • [5] INVIVO VALIDATION OF MR VELOCITY IMAGING
    FIRMIN, DN
    NAYLER, GL
    KLIPSTEIN, RH
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 751 - 756
  • [6] ECHO-PLANAR HIGH-RESOLUTION FLOW VELOCITY MAPPING
    FIRMIN, DN
    KLIPSTEIN, RH
    HOUNSFIELD, GL
    PALEY, MP
    LONGMORE, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) : 316 - 327
  • [7] SPATIAL LOCALIZATION IN 2 DIMENSIONS USING NMR DESIGNER PULSES
    HARDY, CJ
    CLINE, HE
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03): : 647 - 654
  • [8] RAPID NMR CARDIOGRAPHY WITH A HALF-ECHO M-MODE METHOD
    HARDY, CJ
    PEARLMAN, JD
    MOORE, JR
    ROEMER, PB
    CLINE, HE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) : 868 - 874
  • [9] HUMAN ABDOMINAL-AORTA - COMPARATIVE MEASUREMENTS OF BLOOD-FLOW WITH MR IMAGING AND MULTIGATED DOPPLER US
    MAIER, SE
    MEIER, D
    BOESIGER, P
    MOSER, UT
    VIELI, A
    [J]. RADIOLOGY, 1989, 171 (02) : 487 - 492
  • [10] MEASUREMENT OF AORTIC BLOOD-FLOW WITH MR IMAGING - COMPARATIVE-STUDY WITH DOPPLER US
    MATSUDA, T
    SHIMIZU, K
    SAKURAI, T
    FUJITA, A
    OHARA, H
    OKAMURA, S
    HASHIMOTO, S
    TAMAKI, S
    KAWAI, C
    [J]. RADIOLOGY, 1987, 162 (03) : 857 - 861