EFFECTS OF PULSED ULTRASOUND ON THE FROG-HEART .1. THRESHOLDS FOR CHANGES IN CARDIAC-RHYTHM AND AORTIC PRESSURE

被引:40
作者
DALECKI, D [1 ]
KELLER, BB [1 ]
RAEMAN, CH [1 ]
CARSTENSEN, EL [1 ]
机构
[1] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
关键词
PULSED ULTRASOUND; HEART; PREMATURE VENTRICULAR CONTRACTION; AORTIC PRESSURE; BIOEFFECT;
D O I
10.1016/0301-5629(93)90057-U
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High intensity pulsed ultrasound at 1.2 MHz is shown to change the cardiac rhythm and aortic pressure of frog hearts in vivo. Threshold levels for these effects occur at acoustic pressure amplitudes of the order of 10 MPa for 5 ms pulse lengths. Depending upon the phase of the heart cycle, a pulse of ultrasound either may cause a premature ventricular contraction, a reduction in the strength of contraction as measured by the aortic pressure, or an enhanced relaxation of the heart muscle. There is an increase in the effectiveness of the ultrasound with increase in pulse length in the range from 1 to 5 ms.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 7 条
[1]   TEST FOR KIDNEY HEMORRHAGE FOLLOWING EXPOSURE TO INTENSE, PULSED ULTRASOUND [J].
CARSTENSEN, EL ;
HARTMAN, C ;
CHILD, SZ ;
COX, CA ;
MAYER, R ;
SCHENK, E .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) :681-685
[2]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[3]   THRESHOLDS FOR PREMATURE VENTRICULAR CONTRACTIONS IN FROG HEARTS EXPOSED TO LITHOTRIPTER FIELDS [J].
DALECKI, D ;
KELLER, BB ;
CARSTENSEN, EL ;
NEEL, DS ;
PALLADINO, JL ;
NOORDERGRAAF, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (04) :341-346
[4]   TRENDS IN DIAGNOSTIC ULTRASOUND EXPOSURE [J].
DUCK, FA ;
MARTIN, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (11) :1423-1432
[5]   LUNG DAMAGE FROM EXPOSURE TO THE FIELDS OF AN ELECTROHYDRAULIC LITHOTRIPTER [J].
HARTMAN, C ;
CHILD, SZ ;
MAYER, R ;
SCHENK, E ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) :675-679
[6]   PRESSURE THRESHOLD FOR SHOCK-WAVE INDUCED RENAL HEMORRHAGE [J].
MAYER, R ;
SCHENK, E ;
CHILD, S ;
NORTON, S ;
COX, C ;
HARTMAN, C ;
COX, C ;
CARSTENSEN, E .
JOURNAL OF UROLOGY, 1990, 144 (06) :1505-1509
[7]   CALIBRATION OF MEDICAL ULTRASONIC EQUIPMENT - PROCEDURES AND ACCURACY ASSESSMENT [J].
PRESTON, RC ;
BACON, DR ;
SMITH, RA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (02) :110-121