ION-BEAM EQUIPMENT MODIFICATION FOR EXTERNAL-BEAM OPERATION

被引:3
作者
KRAL, J [1 ]
VOLTR, J [1 ]
机构
[1] CZECH TECH UNIV PRAGUE,FAC NUCL SCI & PHYS ENGN,V HOLESOVICKACH 2,CS-18000 PRAGUE 8,CZECH REPUBLIC
关键词
D O I
10.1016/0168-583X(94)95919-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Equipment for analyses by energetic ions has been modified to allow external beam application. An exit window combined with beam charge monitoring, and a system of accelerator vacuum protection are items of modification. To measure the analysing proton integral charge, backscattering from the exit window foil is used. To protect the accelerator vacuum in the case of exit foil breakthrough, a delay of pressure increase along the beam line and a fast closing of the beam line are employed.