CARDIOPULMONARY EXERCISE TESTING AFTER SINGLE AND DOUBLE LUNG TRANSPLANTATION

被引:77
作者
MIYOSHI, S
TRULOCK, EP
SCHAEFERS, HJ
HSIEH, CM
PATTERSON, GA
COOPER, JD
机构
[1] WASHINGTON UNIV,SCH MED,DIV RESP & CRIT CARE,BOX 8053,ST LOUIS,MO 63110
[2] UNIV TORONTO,TORONTO GEN HOSP,FAC MED,DIV THORAC SURG,TORONTO M5G 1L7,ONTARIO,CANADA
[3] WASHINGTON UNIV,SCH MED,DIV CARDIOTHORAC SURG,ST LOUIS,MO 63110
关键词
D O I
10.1378/chest.97.5.1130
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The cardiopulmonary response to exercise was investigated in six single and six double lung transplant recipients using a three-minute incremental work rate protocol on a cycle ergometer. Maximum V̇O2 averaged 44.2 ± 9.2 percent and 48.5 ± 5.0 percent of predicted maximal V̇O2 in the single and double lung transplant groups, respectively. No evidence of ventilatory limitation to exercise was found in either group. Circulatory factors that may have limited exercise capacity included anemia and submaximal heart rates. There was a strong correlation between V̇O2/kg at venous blood lactate level of 2.2 mEq/L and vital capacity/body surface area in the single, but not in the double, lung recipients. Maximum V̇O2 in these lung transplant recipients was comparable to previously published values in heart-lung transplant recipients. The factors that limit maximum exercise capacity after lung transplantation deserve further study.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 34 条
[31]   BIDIRECTIONAL RESPIRATORY FLOWMETER USING HOT-WIRE PRINCIPLE [J].
YOSHIYA, I ;
NAKAJIMA, T ;
NAGAI, I ;
JITSUKAWA, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (02) :360-365
[32]  
Zar J.H., 1974, BIOSTATISTICAL ANAL
[33]  
1986, NEW ENGL J MED, V314, P1140
[34]  
1988, JAMA-J AM MED ASSOC, V259, P2258