HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CREATININE IN SERUM, AND A CORRELATION OF THE RESULTS WITH THOSE OF THE JAFFE AND ENZYMATIC METHODS

被引:27
作者
SCHNEIDERKA, P
PACAKOVA, V
STULIK, K
KLOUDOVA, M
JELINKOVA, K
机构
[1] CHARLES UNIV, DEPT ANALYT CHEM, ALBERTOV 2030, CS-12840 PRAGUE 2, CZECHOSLOVAKIA
[2] CHARLES UNIV HOSP, DEPT CLIN BIOCHEM, CS-12111 PRAGUE 2, CZECHOSLOVAKIA
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 614卷 / 02期
关键词
D O I
10.1016/0378-4347(93)80312-R
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic method for the determination of creatinine in control sera is reported, based on its separation from deproteinated serum components on the ion-exchange material HEMA Bio 1000 SB and ultraviolet detection at 230 nm. Groups of eleven to fourteen samples of human serum and several control materials were simultaneously analysed by the Jaffe, enzymic ultraviolet and enzymic peroxidase aminophenazone methods. Another group (52-115 sera) was analysed for correlations with spectrophotometric methods. The precision of the chromatographic method ranges between 2.0 and 1.0% (relative standard deviation) for serum creatinine concentrations of 115.1 to 471 mumol/l, respectively. A very good accuracy was found in analyses of reference materials Kontrollogen-L and -LP. Some results of analyses of the other control sera were higher and the other lower than those obtained by the Jaffe and enzymic methods, because both interferences and enzyme inhibitors were encountered. Correlations between the chromatographic and spectrophotometric methods were good.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 46 条
[1]   HPLC ANALYSIS OF CREATININE IN HUMAN-PLASMA AND URINE [J].
ACHARI, R ;
MAYERSOHN, M ;
CONRAD, KA .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (06) :278-281
[2]  
AMBROSE RT, 1983, CLIN CHEM, V29, P256
[3]   SUITABLE POTENTIOMETRIC ENZYME SENSORS FOR UREA AND CREATININE [J].
CAMPANELLA, L ;
SAMMARTINO, MP ;
TOMASSETTI, M .
ANALYST, 1990, 115 (06) :827-830
[4]  
CHIOU WL, 1983, J CHROMATOGR, V277, P436, DOI 10.1016/S0378-4347(00)84873-2
[5]   COMPARISON OF PLASMA CREATININE LEVELS IN PATIENTS DETERMINED BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY, AUTOMATED-ANALYSIS, AND BOILING ALKALINE PICRATE METHOD [J].
CHIOU, WL ;
PENG, GW ;
GADALLA, MAF ;
NERENBERG, ST .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1978, 67 (02) :292-293
[6]  
COOK J G H, 1975, Annals of Clinical Biochemistry, V12, P219
[7]   SIMULTANEOUS DETERMINATION OF CREATININE AND URIC-ACID IN SERUM BY HIGH-PERFORMANCE ION-EXCHANGE CHROMATOGRAPHY WITH DIRECT INJECTION [J].
ETOH, T ;
IWATAKE, M ;
MIYAZAKI, M ;
HARADA, K ;
NAKAYAMA, M ;
SUGII, A ;
UJI, Y ;
OKABE, H .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (09) :1565-1575
[8]  
FISER J, 1975, KREATININ BIO LA TES
[9]  
GINMAN RFA, 1985, CLIN CHEM, V31, P331
[10]  
HOLMES EW, 1983, ANN CLIN LAB SCI, V13, P503