CEREBRAL ANEURYSMS - 3-DIMENSIONAL DEMONSTRATION WITH SPIRAL CT

被引:12
作者
RIEGER, J [1 ]
HOSTEN, N [1 ]
LEMKE, AJ [1 ]
LANGER, R [1 ]
LANKSCH, WR [1 ]
FELIX, R [1 ]
机构
[1] FREE UNIV BERLIN,KLINIKUM RUDOLF VIRCHOW,NEUROCHIRURG KLIN & POLIKLIN,W-1000 BERLIN 33,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1994年 / 160卷 / 03期
关键词
CT ANGIOGRAPHY; SPIRAL CT; 3-D RECONSTRUCTION; INTRACRANIAL ANEURYSMS;
D O I
10.1055/s-2008-1032408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, the possibility of non-invasive, three-dimensional demonstration of aneurysms of the basal cerebral arteries by means of spiral CT was investigated. The first step was to obtain exact definition of optimal examination parameters. Angio CTs at appropriate levels were performed on 10 subjects and time/density curves of the arterial and venous phases obtained in order to optimise the beginning of the arterial spiral CT series. The second step in this investigation was to examine 7 patients; in 6 of these basal aneurysms had been demonstrated by DSA. By means of multiplanar three-dimensional reconstruction from the data of the spiral CT it was possible to demonstrate 7 aneurysms with a diameter between 5 and 18 mm. Their position and relationship to the bony skull was also shown.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 10 条
[1]   3D-CT AND ANGIOGRAPHY OF PHANTOMS OF THE PELVIC VESSELS - DEMONSTRATION OF THE ARTERIAL SUPPLY OF THE ACETABULUM [J].
BACHMANN, G ;
PFEIFER, T ;
SPIES, H ;
KATTHAGEN, BD .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (03) :214-220
[2]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[3]  
JELLINGER K, 1979, CEREBRAL ANEURYSMS, P5
[4]  
Kalender W A, 1990, Rontgenpraxis, V43, P323
[5]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[6]   INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY AND THE SURGICAL-TREATMENT OF INTRACRANIAL ANEURYSMS AND VASCULAR MALFORMATIONS [J].
MARTIN, NA ;
BENTSON, J ;
VINUELA, F ;
HIESHIMA, G ;
REICHER, M ;
BLACK, K ;
DION, J ;
BECKER, D .
JOURNAL OF NEUROSURGERY, 1990, 73 (04) :526-533
[7]  
RUBIN GD, 1992, DIAGN IMAGING, V8, P66
[8]   SPIRAL CT WITH 3D-SURFACE DEMONSTRATION FOR THE EVALUATION OF SOLITARY PULMONARY-LESIONS [J].
STRUNK, H ;
SCHWEDEN, F ;
SCHILD, H ;
THELEN, M .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (01) :26-30
[9]  
Wegener O. H., 1992, GANZKORPERCOMPUTERTO
[10]   COLOR-CODED 3-DIMENSIONAL RECONSTRUCTION FROM SPIRAL CT DATA SETS - IMPROVEMENT FROM THE PHYSICAL POINT-OF-VIEW [J].
WUNDERLICH, AP ;
LENZ, M ;
KIRSTEN, R ;
GERHARDT, P .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (03) :221-224