STATE OF THE MARKET - A REVIEW OF AMBULATORY BLOOD-PRESSURE MONITORING DEVICES

被引:99
作者
OBRIEN, E [1 ]
ATKINS, N [1 ]
STAESSEN, J [1 ]
机构
[1] UNIV ZIEKENHUIS GASTHUISBERG, INWENDIGE GENEESKUNDE CARDIOL, KLIN LAB HYPERTENSIE, LOUVAIN, BELGIUM
关键词
BLOOD PRESSURE MONITORING; AMBULATORY; EQUIPMENT DESIGN; EVALUATION STUDIES; DURABLE MEDICAL EQUIPMENT;
D O I
10.1161/01.HYP.26.5.835
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any validation studies assessing accuracy and performance. Of the 43 devices available 18 have been validated according to the protocols of the Association for the Advancement of Medical Instrumentation (AAMI) or the British Hypertension Society (BHS) in 25 reported studies. In 9 of these studies the protocol was not adhered to, and the results, which are therefore questionable, are noted but not considered further. Fourteen devices were evaluated according to the accuracy criteria of both protocols, and of these 9 fulfilled the requirements. From this review of 43 devices on the market it may be concluded that: at the time of writing, there is published evidence for only 9 devices meeting the generally accepted AAMI and BHS criteria for accuracy and performance; these are the A&D TM-2420 models 6 and 7 and TM-2421, CH-Druck, Nissei ABPM DS-240, Profilomat, QuietTrak, and SpaceLabs SL-90202 and SL-90207.
引用
收藏
页码:835 / 842
页数:8
相关论文
共 98 条
[1]   CONCURRENT VALIDITY STUDIES OF BLOOD-PRESSURE INSTRUMENTATION - THE PHILADELPHIA BLOOD-PRESSURE PROJECT [J].
BARKER, WF ;
HEDIGER, ML ;
KATZ, SH ;
BOWERS, EJ .
HYPERTENSION, 1984, 6 (01) :85-91
[2]   ACCURACY OF AMBULATORY BLOOD-PRESSURE DETERMINATION - A COMPARATIVE-STUDY [J].
BARTHELEMY, JC ;
GEYSSANT, A ;
AUBOYER, C ;
ANTONIADIS, A ;
BERRUYER, J ;
LACOUR, JR .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (05) :461-466
[3]  
BRUNNER HR, 1983, J HYPERTENSION S2, V1, P291
[4]   AGE AND BLOOD-PRESSURE MEASUREMENT - EXPERIENCE WITH THE TM2420 AMBULATORY BLOOD-PRESSURE MONITOR AND ELDERLY PEOPLE [J].
CLARK, S ;
FOWLIE, S ;
PANNARALE, G ;
BEBB, G ;
COATS, A .
AGE AND AGEING, 1992, 21 (06) :398-403
[5]  
CLARK S, 1991, OBSTET GYNECOL, V77, P152
[6]  
CLARK S, 1991, J HUM HYPERTENS, V5, P77
[7]  
CLEMENT DL, 1991, J HYPERTENS, V9, pS51
[8]  
CLEMENT DL, 1983, J HYPERTENS S2, V1, P296
[9]  
Conroy R M, 1994, Blood Press, V3, P283, DOI 10.3109/08037059409102275
[10]   MEASUREMENT ERROR IN THE HAWKSLEY RANDOM ZERO SPHYGMOMANOMETER - WHAT DAMAGE HAS BEEN DONE AND WHAT CAN WE LEARN [J].
CONROY, RM ;
OBRIEN, E ;
OMALLEY, K ;
ATKINS, N .
BRITISH MEDICAL JOURNAL, 1993, 306 (6888) :1319-1322