MAGNETIC-RESONANCE, A NEW METHOD FOR MEASURING BLOOD-FLOW IN HEMODIALYSIS FISTULAS

被引:38
作者
OUDENHOVEN, LFIJ [1 ]
PATTYNAMA, PMT [1 ]
DEROOS, A [1 ]
SEEVERENS, HJJ [1 ]
REBERGEN, SA [1 ]
CHANG, PC [1 ]
机构
[1] UNIV HOSP LEIDEN,DEPT NEPHROL,2300 RC LEIDEN,NETHERLANDS
关键词
D O I
10.1038/ki.1994.116
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Blood flow through arteriovenous fistulae in patients undergoing hemodialysis needs to be within a certain range for optimal management. Magnetic resonance (MR) velocity mapping is a new modality that allows the noninvasive measurement of blood flow volume. This technique was applied in 13 patients with either a Brescia-Cimino shunt (N = 6) or a Polytetrafluoroethylene graft (Goretex, N = 7). Fistula flow volume measured by MR velocity mapping was 1386 +/- 411 ml/min (mean +/- SD, range 644 to 1921 ml/min). Interstudy reproducibility of MR velocity mapping was good (r = 0.94). MR velocity mapping derived flow volumes showed good correlation with values obtained with an indicator dilution technique using Indocyanine Green (ICG) which was performed simultaneously in eight patients (r = 0.86). We conclude that MR velocity mapping is an accurate noninvasive method to quantify flow volume through arteriovenous fistulae in patients requiring hemodialysis.
引用
收藏
页码:884 / 889
页数:6
相关论文
共 37 条
[1]   MEASUREMENT OF BLOOD FLOW AND VOLUME IN THE FOREARM OF MAN - WITH NOTES ON THE THEORY OF INDICATOR-DILUTION AND ON PRODUCTION OF TURBULENCE, HEMOLYSIS, AND VASODILATION BY INTRA-VASCULAR INJECTION [J].
ANDRES, R ;
ZIERLER, KL ;
ANDERSON, HM ;
STAINSBY, WN ;
CADER, G ;
GHRAYYIB, AS ;
LILIENTHAL, JL .
JOURNAL OF CLINICAL INVESTIGATION, 1954, 33 (04) :482-504
[2]  
BELL PRF, 1990, CLIN DIALYSIS, P26
[3]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[4]   POPLITEAL AND TIBIOPERONEAL ARTERIES - FEASIBILITY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY AND PHASE-VELOCITY MAPPING [J].
CAPUTO, GR ;
MASUI, T ;
GOODING, GAW ;
CHANG, JM ;
HIGGINS, CB .
RADIOLOGY, 1992, 182 (02) :387-392
[5]  
DENCKER H, 1971, EUR SURG RES, V4, P81
[6]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[7]   IMAGING OF HEMODIALYSIS FISTULAS - LIMITATIONS OF MR ANGIOGRAPHY [J].
GEHL, HB ;
BOHNDORF, K ;
GLADZIWA, U ;
HANDT, S ;
GUNTHER, RW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) :271-275
[8]  
GOTHLIN J, 1977, INVEST UROL, V15, P167
[9]  
GOTHLIN J, 1972, ACTA RADIOL, V14, P113
[10]  
GREENWOOD RN, 1985, CLIN NEPHROL, V23, P189