SEPARATION OF CFC-12 FROM AIR BY POLYIMIDE HOLLOW-FIBER MEMBRANE MODULE

被引:21
作者
CHUNG, IJ
LEE, KR
HWANG, ST
机构
[1] UNIV CINCINNATI,DEPT CHEM ENGN,CTR EXCELLENCE MEMBRANE TECHNOL,CINCINNATI,OH 45221
[2] KANGWEON NATL UNIV,COLL ENGN,DEPT CHEM ENGN,CHUNCHON 200701,SOUTH KOREA
关键词
AIR CFC-12; POLYIMIDE MEMBRANE; GAS SEPARATION; SEPARATION FACTOR; HOLLOW-FIBER; PERMEATION RATE;
D O I
10.1016/0376-7388(95)00058-K
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The performance of a polyimide membrane module was investigated for the separation of air/CFC-12 mixtures as a function of temperature, pressure, stage cut, and feed gas composition. The ideal separation factor was in the range of 60 to 200 in the ranges of temperature and pressure studied. There was a substantial decrease in the permeation rates of the more permeable gas (air) through the glassy polymer (polyimide) caused by the presence of the other gas (CFC-12). However, the permeation rate of CFC-12 (dichlorodifluoromethane, CCl2F2), which is the less permeable gas, was increased by the presence of the more permeable gas (air). It was found that experimental data were well correlated with prediction of mathematical models.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 15 条
[11]   THE SELECTIVE PERMEATION OF GASES THROUGH POLYMERS [J].
STERN, SA ;
FRISCH, HL .
ANNUAL REVIEW OF MATERIALS SCIENCE, 1981, 11 :523-550
[12]  
STONE J, 1991, CHEM ENG JUN, P43
[13]   INCINERATION OF CFC-12 BY BURNER METHODS [J].
TOKUHASHI, K ;
URANO, Y ;
HORIGUCHI, S ;
KONDO, S .
COMBUSTION SCIENCE AND TECHNOLOGY, 1990, 72 (1-3) :117-129
[14]   A VISCOSITY EQUATION FOR GAS MIXTURES [J].
WILKE, CR .
JOURNAL OF CHEMICAL PHYSICS, 1950, 18 (04) :517-519
[15]  
1989, DESTRUCTION TECHNOLO